Page 2
Please read this instruction manual carefully before use. (GB) Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice. Importeur Airpress, P.O. Box 114, NL-8900 AC Leeuwarden www.airpress.nl...
10. Troubleshooting guide page 34 1. PREFATORY NOTES Buying your AIRPRESS compressor installation, you have become the owner of a compressor installation with a high performance and reliability level. Correct use and regular maintenance will increase the life of the compressor.
2.0 SAFETY INSTRUCTIONS Important: please read and observe the following safety instructions before using the machine. • Nobody must be allowed to use the compressor unless they have read the instruction manual and have been instructed in the regulations to follow for correct and safe use.
excessive heat, oil and sharp objects. • Never leave the machine unattended with the power supply "on". Also disconnect the power cable when: - you leave the machine, even for a short time - not in use - carrying out maintenance work - changing attachment or moving the machine.
Page 7
tank may reduce the tank's strength and cause an extremely hazardous condition. Welding on the tank in any manner will void the warranty. Check the manufacturer's maximum pressure rating for air tools and accessories. Compressor outlet pressure must be regulated so as to never exceed the maximum pressure rating of the tool.
4. SPECIFICATIONS Order number 36646 Pump Oil-lubricated direct drive Motor 1,5 HP/1,1 kW Voltage Single Phase 230 Volt Air tank capacity 5 litres Oil tank capacity 0,25 litres Cut-in Pressure 6 bar Cut-out Pressure 8 bar Max. charge 30% per 60 minutes Sound pressure 77 dB(A)/7 m Air intake capacity...
Serious damage can result running the compressor without oil. The pump is shipped with oil from the factory. If necessary refill with Airpress compressor oil, order No 36398, until the oil reaches the center of the red circle in the sight glass WARNING Drain the tank to release all tank air pressure before removing the oil fill cap.
Page 10
Location of the Air Compressor The air compressor should always be located in a clean, dry, and well-ventilated environment. The unit should have at minimum, 12 inches of space on each side. The air filter intake should be free of any debris or obstructions. Check the air filter on a daily basis to be sure it is clean and in working order.
7. OPERATION PROCEDURES Daily start-up Procedures 1. Set the Auto-On/Off lever to the Off position. 2. Check the air compressor visually for any damage or obstruction. 3. Close the drain valve. 4. Check the oil level of the pump. 5. Attach the air hose to the quick coupler by pulling back on the outer sleeve of the quick.
Page 12
Be sure the gasket is between the sight glass and the pump crankcase. 8. Refill the compressor pump with Airpress compressor oil at slow intervals until the oil reaches the center of the red circle in the sight glass (oil tank capacity 0,25 litres).
Cleaning Air Filter To clean the air intake filter, be sure to do the following: 1. Turn the unit off and unplug the power cord from the receptacle. 2. Allow the compressor time to cool if it has been in operation. 3.
Page 14
Problem Possible Correction Air leaks at the check A defective check valve results in a constant air leak at the valve or at the pressure release valve when there is pressure in the tank pressure relief valve. and the compressor is shut off. Drain the tank, then remove and clean or replace the check valve.
Page 15
Danger plates The plates fitted on the compressor unit are part of the machine; they have been applied for safety purposes and must not be removed or spoiled for any reason.
Page 16
Vorstvrij opstellen Frostfrei aufstellen Frost-proof installation Installer à l’abri du gel Instalacion a prueba de heladas Pas op voor hete delen Heisse Teile Beware of hot parts Faites attention aux pièces chaudes Tenga cuidado con las piezas calientes Regelmatig oliepeil controleren Regelmäßig Ölstand kontrollieren Regularly check oil level Contrôler régulièrement le niveau d’huile...
Page 17
EC-declaration of conformity We, Airpress, P.O. Box 114, 8900 AC Leeuwarden, The Netherlands, taking full responsibility, declare that the products compressors LHR 215/5 to which this declaration refers, comply with the machinery directive 98/37/EC, the EMC directive 89/336/EC, the low tension directive 73/23/EC and the directive 2000/14/EC.
Page 18
EC-declaration of conformity We, Airpress, P.O. Box 114, 8900 AC Leeuwarden, The Netherlands, taking full responsibility, declare that the products compressors LHR 215/5 to which this declaration refers, comply with the machinery directive 98/37/EC, the EMC directive 89/336/EC, the low tension directive 73/23/EC and the directive 2000/14/EC.
Need help?