Please file and use this manual together with the service manual for Model No. CS-F24DTE5 CU-B24DBE5
CS-F28DTE5 CU-B28DBE5 CS-F28DTE5 CU-B28DBE8 CS-F34DTE5 CU-B34DBE5 CS-F34DTE5 CU-
B34DBE8 CS-F43DTE5 CU-B43DBE8 CS-F50DTE5 CU-B50DBE8, Order No. MAC0509063C2 and CS-
F18DTE5 CU-B18DBE5, Order No. MAC0602018C2.

TABLE OF CONTENTS

1 Features ------------------------------------------------------------- 2
1.1. Twin ----------------------------------------------------------- 2
2 Product Specification ------------------------------------------- 3
2.1. CS-F18DTE5 CU-B34DBE5 ---------------------------- 3
2.2. CS-F18DTE5 CU-B34DBE8 ---------------------------- 4
2.3. CS-F24DTE5 CU-B43DBE8 ---------------------------- 5
2.4. CS-F28DTE5 CU-B50DBE8 ---------------------------- 6
3 Twin Systems ------------------------------------------------------ 7
3.1. Installation Manual ---------------------------------------- 7
4 Troubleshooting Guide ----------------------------------------- 9
4.1. During twin operation ------------------------------------- 9
CS-F18DTE5 CU-B34DBE5
CS-F18DTE5 CU-B34DBE8
CS-F24DTE5 CU-B43DBE8
CS-F28DTE5 CU-B50DBE8
PAGE
© 2006 Panasonic HA Air-Conditioning (M) Sdn Bhd
(11969-T). Unauthorized copying and distribution is a
violation of law.
Order No. MAC0605029C2
Air Conditioner
PAGE

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic CS-F18DTE5

  • Page 1: Table Of Contents

    2.4. CS-F28DTE5 CU-B50DBE8 ---------------------------- 6 3 Twin Systems ------------------------------------------------------ 7 3.1. Installation Manual ---------------------------------------- 7 4 Troubleshooting Guide ----------------------------------------- 9 4.1. During twin operation ------------------------------------- 9 © 2006 Panasonic HA Air-Conditioning (M) Sdn Bhd (11969-T). Unauthorized copying and distribution is a violation of law.
  • Page 2: Features

    1 Features 1.1. Twin 1.1.1. Twin Operation • Simultaneous air conditioning of wide spaces and corners is possible. Indoor units with same horsepowers can even be used in combination. • Master unit and slave-units can be set automatically in twin systems. No address setting is necessary. •...
  • Page 3: Product Specification

    2 Product Specification 2.1. CS-F18DTE5 CU-B34DBE5 ITEM / MODEL Indoor Unit Outdoor Unit CS-F18DTE5 × 2 Main Body CU-B34DBE5 Remote CZ-RD513C (Wired) Control CZ-RL513T (Wireless) Cooling Capacity 10.0 BTU/h 34,100 Heating Capacity 11.2 BTU/h 38,200 Refrigerant Charge-less Standard Air Volume for High,...
  • Page 4: Cs-F18Dte5 Cu-B34Dbe8

    2.2. CS-F18DTE5 CU-B34DBE8 ITEM / MODEL Indoor Unit Outdoor Unit CS-F18DTE5 × 2 Main Body CU-B34DBE8 Remote CZ-RD513C (Wired) Control CZ-RL513T (Wireless) Cooling Capacity 10.0 BTU/h 34,100 Heating Capacity 11.2 BTU/h 38,200 Refrigerant Charge-less Standard Air Volume for High, /min 3316 210 ×...
  • Page 5: Cs-F24Dte5 Cu-B43Dbe8

    4.64 4.69 4.74 Running Current Cooling 7.85 8.00 8.15 Heating 7.60 7.80 8.00 Starting Current Power Factor Cooling Heating *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 3~380V,400V, 415V 50Hz...
  • Page 6: Cs-F28Dte5 Cu-B50Dbe8

    Power Consumption Cooling 5.11 5.16 5.28 Heating 4.98 5.03 5.08 Running Current Cooling Heating Starting Current Power Factor Cooling Heating *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 3~380V,400V, 415V 50Hz...
  • Page 7: Twin Systems

    3 Twin Systems 3.1. Installation Manual...
  • Page 9: Troubleshooting Guide

    4 Troubleshooting Guide 4.1. During twin operation System example 1. The main power is turned on while the transmission wires between the indoor units are not connected. (open circuit at A or B) Symptom Remote control unit: “check” flashes Error code: F30-01 (connected indoor capacity error) Indoor unit No.
  • Page 10 Indoor unit: LED1 on P.C.B flashes Outdoor unit: LED6, 7 on P.C.B flashes 4. The main power is turned on and the connection wire is all ok. If operation starts in this condition, combination of the B50DBE8 outdoor unit and F24DB4E5 indoor unit will result in abnormal operation.

Table of Contents