Download Print this page
Yunca Heating HOBSON Maintenance Manual

Yunca Heating HOBSON Maintenance Manual

Solid fuel burner

Advertisement

Quick Links

A GUIDE TO MAINTAINING YOUR
Yunca Woodburners and Multifuels feature
very similar basic designs throughout the
range, so when it comes to maintaining
your fire the same procedures may be
followed for different models.
To assist with identifying fires and associated
spare parts, please refer to the online spare
parts (woodburner, multifuel) guide:
http://www.yunca.co.nz/Instructions/index.htm
Yunca recommends you regularly check your
burner to ensure optimum performance. To
save on maintenance costs there are a
number of procedures that, with due care and
attention, can be carried out by the owner.
This includes the following:
-
replacing the glass / glass seal
-
replacing the door rope / ash door rope.
-
replacing the door handle / door handle
shaft
-
replacing firebricks / combustion plates / air
tubes
The following is a guideline to assist with
some of these tasks.
Remember that your safety is paramount, so if
there is any doubt please contact your local
Yunca agent or a service firm (maintenance
may also be carried out by the same firm that
offers chimney cleaning, for example).
Yunca recommends that the flue system is
checked and cleaned annually.
Yunca Heating Solid Fuel Maintenance Guide
YUNCA SOLID FUEL BURNER
1. REPLACING THE GLASS,
GLASS SEAL and DOOR ROPE
Glass may be cleaned by dipping a damp paper
towel in ash and wiping the cold glass. Buff with a
clean, damp paper towel. Glass may blacken
when a fire is turned down, and this will normally
burn off when next operating at a higher
temperature.
If there is a very sticky, dark deposit on the glass
this is creosote, caused by burning wet wood or
not having enough heat in the fire bed before
turning the fire down. Creosote may be difficult to
remove. Avoid scratching the glass. Avoid harsh
chemicals or the glass may become pitted. Should
you use ANY cleaner on the glass, you must rinse
well before use.
Avoid creosote build up by ensuring your firewood
is well seasoned. Creosote can also cause
chimney blockages.
N.B. When door / ash door rope has been
replaced it will be necessary to adjust the door
handle shaft (where fitted). Refer to section 2.
1A. "NEW MODEL" MULTIFUEL FIRES
(FREESTANDING & INBUILT), HOBSON,
FITZROY, QEWB (except QEWB2000),
and QEWB VARIANTS (FOCUS,
RADIANT, etc).
(Wegj and Blenz: Refer 1B, 1C).
You may leave the door frame in place on the
fire when changing glass, glass seals and
ropes. It is not advisable to reuse old glass seal
as it may not give an adequate seal and it will
be very difficult to fit without adhesive.
April 2010

Advertisement

loading

Summary of Contents for Yunca Heating HOBSON

  • Page 1 Yunca recommends that the flue system is checked and cleaned annually. Yunca Heating Solid Fuel Maintenance Guide April 2010...
  • Page 2 If you find the rope is too long (a small amount DOOR ROPE left over is ok, more than 15mm needs – 1A. MULTI, HOBSON, FITZROY, QEWB, etc trimming) this MAY mean the rope has been continued. stretched, try removing the rope and refitting it.
  • Page 3 Qewb MF series) try adjusting the catch pin the door. To close the door, start with the (0215BQM). handle at 12 o’clock, push the door closed, and turn the handle down to about the “4 o’clock” position. Yunca Heating Solid Fuel Maintenance Guide April 2010...
  • Page 4 3D. “NEW MODEL” MULTI (FREESTANDING and INBUILT) CLEAN AIR versions of the HOBSON and These models use castings rather than bricks, FITZROY have a SQUARE air tube (1607HSC) although after use they may not look it! fitted, it sits on top of the bricks, under the combustion plate.

This manual is also suitable for:

FitzroyWegj 2000QewbBlenz