Do you have a question about the WA90F5S2 and is the answer not in the manual?
Questions and answers
Sipho Mtolo
January 25, 2025
Machine not taking out water
1 comments:
Mr. Anderson
February 10, 2025
The Samsung WA90F5S2 washing machine may not be draining water due to the following reasons: - The drain hose is not positioned correctly (for models without a pump). - The drain hose is frozen. - The drain hose is clogged. - If water does not drain within 30 minutes, a buzzer will sound, and the remaining time indicator will display "5E".
This answer is automatically generated
Richard Candy
May 6, 2025
I have a WA13F5S2 top loading washing machine.
The colde water inlet valve had a fault and burnt out.
I have replaced the cold water valve but no water flows through the value and there is no voltage on control connectors to the valve.
I confirmed that the cold water valve works by connecting he HOT water valve control power connection to the COLD water valve.
I now think that a fuze may have blown on the main circuit board.
I would now like to know how to access the main circuit board and replace the fuse, assuming that the fuse can be replaced.
Need help?
Do you have a question about the WA90F5S2 and is the answer not in the manual?
Questions and answers
Machine not taking out water
The Samsung WA90F5S2 washing machine may not be draining water due to the following reasons:
- The drain hose is not positioned correctly (for models without a pump).
- The drain hose is frozen.
- The drain hose is clogged.
- If water does not drain within 30 minutes, a buzzer will sound, and the remaining time indicator will display "5E".
This answer is automatically generated
I have a WA13F5S2 top loading washing machine. The colde water inlet valve had a fault and burnt out. I have replaced the cold water valve but no water flows through the value and there is no voltage on control connectors to the valve. I confirmed that the cold water valve works by connecting he HOT water valve control power connection to the COLD water valve. I now think that a fuze may have blown on the main circuit board. I would now like to know how to access the main circuit board and replace the fuse, assuming that the fuse can be replaced.