Schematic Diagrams - Sharp 15JF-25S Service Manual

Table of Contents

Advertisement

15JF-25S
Description
SAFETY NOTE:
1. DISCONNECT THE AC PLUG FROM THE AC
OUTLET BEFORE REPLACING PARTS.
2. SEMICONDUCTOR HEAT SINKS SHOULD BE
REGARDED AS POTENTIAL SHOCK HAZARDS
WHEN THE CHASSIS IS OPERATING.
IMPOTANT SAFETY NOTE:
PARTS MARKED WITH «
IMPORTANT FOR MAINTAINING THE SAFETY
OF THE SET. BE SURE TO REPLACE THESE
PARTS WITH SPECIFIED ONES FOR MAINTAIN-
ING THE SAFETY AND PERFORMANCE OF THE
SET.
CAUTION
This circuit diagram is original one, there-
fore there may be slight difference from
yours.
Waveforms

SCHEMATIC DIAGRAMS

» (
) ARE
!
26
NOTE:
1. The unit of resistance «ohm»is omitted (K=1000
ohms. M= Megaohm).
2. All resistors are 1/16 watt. unless otherwise noted.
µ
3. All capacitors are
F, unless otherwise noted (P=
µµ
F).
4. The capacitor with Part No. RC-FZ9XXXBMNJ is
designed to with stand 63V.
5. The capacitor with Part No. RC-FZ4XXXBMNJ is
designed to with stand 50V.
SERVICE PRECAUTION:
THE AREA ENCLOSED BY THIS LINE (
IS DIRECTLY CONNECTED WITH AC MAINS
VOLTAGE.
WHEN SERVICING THE AREA, CONNECT AN
ISOLATING TRANSFORMER BETWEEN TV
RECEIVER AND AC LINE TO ELIMINATE HAZ-
ARD OF ELECTRIC SHOCK.
WAVEFORM MEASUREMENT CONDITION:
Colour bar generator signal of 70 dB from RF input.
)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents