3-Pin to 5-Pin Conversion 5. OPERATING INSTRUCTIONS......... 12 Back Pack Overview Connecting the Back Pack Controller DMX Mode Manual Mode Master/Slave Operation Using ProFan with a Smoke Machine 6. TROUBLESHOOTING AND MAINTENANCE....19 Troubleshooting Replacing the Fuse Cleaning 7. APPENDIX............... 21 Limited Warranty...
It can operate from 100 to 240VAC. Multiple ProFans can also slave together to increase air flow or to achieve complex flow patterns for special effects. The ProFan is designed to mount upon a stand or (using ProBurger Accessory clamps or couplers) suspend from a truss or other suitable support.
Preventing Fire and Electric Shock Always ground (earth) the machine electrically. ProFan has a built-in speed control. Do not connect ProFan to any external solid-state speed control device or dimmer circuit. Disconnect the machine from power before removing any components or servicing, and when not in use.
As delivered, the ProFan is ready for stand alone use. Included with the ProFan is a yoke assembly for mating the unit to a floor stand or suspension clamp. The yoke assembly easily attaches to the ProFan using the provided fasteners and wrench.
7. Tighten the Allen bolt and the T-Handle until the yoke assembly is fixed and not easily moved. 8. At this point the ProFan is ready for mating with a stand or clamp. Grip the fan by its tubular housing brackets when lifting...
Support Stand A professional stand, rated to support a weight greater than the unit, must be used to support the ProFan. TMB ProStands, supplied with a PRXTVMP adapter, provide a reliable floor- standing solution...
ProFan Operating Manual 4. R EMOTE ONTROL Basics of DMX Control There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A fixture capable of receiving DMX- 512 will require one or a number of sequential channels. The user must assign a starting address on the fixture that indicates the first channel reserved in the lighting console.
ProFan Operating Manual Minimum 2-conductor twisted pair plus a shield Maximum capacitance between conductors – 22 pF/ft. Maximum capacitance between conductor and shield – 41 pF/ft. Maximum resistance of 14.5 ohms / 1000 ft. Characteristic impedance of 80 – 110 ohms...
ProFan Operating Manual CAUTION: Another consideration to prevent the corruption of DMX data is to not allow contact between the common (pin 1) of a DMX cable and the fixture’s chassis ground. Grounding the common can cause a ground loop, and your fixture may perform erratically.
ProFan Operating Manual 5. O PERATING NSTRUCTIONS Back Pack Overview XLR 3-pin male connector to ProFan DMX/MANUAL LCD Display Mode switch Button: 1. Hold down and slide DMX512 input & Slide Fader Control: fader to set DMX output XLR 5-pin 1.
ProFan Operating Manual Connecting the Back Pack Controller With rear fan power switch in OFF position: Connect the integral male XLR on the Back Pack directly to the integral female XLR on the fan body. If desired, the Back Pack can be removed and connected using a standard 3-pin XLR microphone cable up to 60 ft / 20 m in length.
Page 14
Pack by locating into the bottom housing slot. CAUTION: Double-check that the Back Pack is securely fixed to the fan housing prior to use. Note: Ensure the ProFan is pointed in a direction where considerable wind will not cause a disturbance or any safety issues.
When the recessed switch on the Back Pack is switched to "DMX", the display will indicate that the unit is in DMX Mode and will display the current address of the ProFan. If no incoming DMX signal is detected, the display will then read "No DMX Found".
ProFan Operating Manual Manual Mode When the recessed switch on the Back Pack is switched to "MANUAL", the display will indicate that the unit is in Manual Mode. The display will also indicate the current speed of the fan, based on the position of the fader and whether the Full Speed button is depressed.
"slave" ProFan input. Continue connecting ProFans output to input as needed, up to nine units total. Connect the 5-pin male DMX terminator to the DMX output of the last ProFan in the chain Set the mode switch of the master controller to "MANUAL", and...
ProFan Operating Manual Using ProFan with a Smoke Machine When using ProFan with smoke, fog or hazer machines, place the fan behind the machines as illustrated below. Do not place the fan in front of the machine. This will cause residue build-up on the fan blades and degrade the quality of the smoke, fog, or haze.
ProFan Operating Manual 6. T ROUBLESHOOTING AND AINTENANCE Troubleshooting Problem Symptom/Cause Suggested Remedy Display says "No Connect DMX DMX Found" Power is supplied, but fan Press button and move Incorrect DMX does not operate fader until correct address via DMX...
ProFan Operating Manual Cleaning Clean the outside of the fan with a damp cloth only. Do not use solvents. Periodic cleaning of the fan blades and grilles is necessary to maintain peak performance. Cleaning frequency depends on the operating environment. Inspect the fan regularly for dust and smoke residue buildup.
ProFan products are warranted against defective materials or workmanship for a period of 12 months from the date of shipment. Parts and components that are not the product of the Seller (TMB) shall be subject only to the terms of any warranty that may be extended by the original manufacturer.
Need help?
Do you have a question about the ProFan and is the answer not in the manual?
Questions and answers