12
Feeding motion of the top feed dog
.05.12
Requirement
When the needle bar is positioned 0.6 mm past t.d.c (adjustment hole 1) and the maximum
stitch length is set, lever 3 should not move when the feed reverse key is operated.
Fig. 12 - 12
While continuously operating the feed reverse key, adjust eccentric 1 (screws 2) so that
the slot is pointing towards the operator and lever 3 does not move.
2
1
4
1
3
49-030
Adjustment
6
3
4
5
12 - 15