Component Description - Kenwood KDC-5090B Service Manual

Table of Contents

Advertisement

KDC-5090B/BY
SWITCH UNIT (X13-99XX-X4)
Ref. No.
Component Name
IC1
LC75808W
IC2
RS-171
Q1
DTA114EUA or KRA302
Q3
2SD2114K
Q4
2SD2114K
Q5
2SC2412K or 2SD601A
Q6
DTA114EUA or KRA302
Q7
DTC143ZK
ELECTRIC UNIT (X25-87X2-7X)
Ref. No.
Component Name
IC1
UPD703033GC117
or UPD703033GC145
IC2
TDA7407D
HD74HC02FP
IC3
or TC74HC02AF
IC4
TA8263BH
IC7
TDA7479D
IC8
S-80837ANNP
Q1
DTC143TUA or KRC410
Q2
DTC143TUA or KRC410
Q5
DTC143TUA or KRC410
Q6
DTC143TUA or KRC410
Q7
DTA124EUA or KRA303
Q11
2SC4081 or 2SD1819A
Q12
2SB1548(P)
Q13
2SA1576A or 2SB1218A
Q14
2SC4081 or 2SD1819A
Q15
2SB1548(P)
Q16
DTC124EUA or UN5212
Q17
DTA124EUA or KRA303
Q18
2SD2375
Q19
DTC124EUA or UN5212
Q20
DTA124EUA or KRA303
4

COMPONENT DESCRIPTION

Application / Function
LCD driver with the key matrix
Remote sensor IC
Key-permission SW
Red LED SW
Green LED SW
VLCD AVR
REMO SW
Dimmer SW
Application / Function
System MI-COM.
E.VOL & N.C.MPX IC
Mute logic
Power AMP. IC
RDS decoder
Reset IC
Pre mute (Front L)
Pre mute (Front R)
Pre mute (Rear L)
Pre mute (Rear R)
Mute driver
BU 5V AVR
SW 5V
A8V AVR
SW14V SW
SERVO +B AVR
ILL +B SW
Operation / Condition / Compatibility
For the key scanning start
When a base goes Hi, RED LEDs are turned on.
When a base goes Hi, GREEN LEDs are turned on.
While a base goes Lo, PAN 5V is supplied to the Remote
sensor IC.
Usually Q7's base goes Hi. When DIMMER mode is
selected, pulse wave shape is applied to Q7's base.
Operation / Condition / Compatibility
2-input NOR x 4
When BU 5V voltage is less than 3.7V, IC outputs Lo.
When Q1's base goes Hi, Pre-output is muted.
When Q2's base goes Hi, Pre-output is muted.
When Q5's base goes Hi, Pre-output is muted.
When Q6's base goes Hi, Pre-output is muted.
When BU detection SW or System RESET or MI-COM.'s
Pre-mute is working, a base goes Lo, and Q7 is turned on.
While BACKUP is applied, AVR outputs +5V.
Q11 and Q12 are inverted Darlington connection.
While a base goes Lo, SW 5V is supplied to the
microprocessor peripheral circuits.
When Q14's base goes Hi, A8V AVR outputs 8V.
A8V AVR and SERVO +B AVR ON/OFF control
While Q16's base goes Hi, Q17 is turned on, A8V AVR and
SERVO +B AVR are working.
When Q18's base goes Hi, SERVO +B AVR outputs 8V.
ILL +B AVR ON/OFF control
While Q19's base goes Hi, Q20 is turned on, and ILL +B
AVR is working.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kdc-5090by

Table of Contents