READ ALL INSTRUCTIONS BEFORE USE
WARNING
For your safety, the information in this manual must be followed to minimize the risk of fire or
explosion, electric shock, or to prevent property damage, personal injury, or loss of life.
SAFETY INSTRUCTIONS FOR INSTALLATION
Exhaust/Ducting:
• Gas dryers MUST be exhausted to the outside.
Failure to follow these instructions can result in fire or
death.
• The dryer exhaust system must be exhausted to
the outside of the dwelling. If the dryer is not
exhausted outdoors, some fine lint and large
amounts of moisture will be expelled into the
laundry area. An accumulation of lint in any area of
the home can create a health and fire hazard.
• Use only rigid metal or flexible metal 4-in.
diameter ductwork inside the dryer cabinet or for
exhausting to the outside. Use of plastic or other
combustible ductwork can cause a fire. Punctured
ductwork can cause a fire if it collapses or becomes
otherwise restricted in use or during installation.
• Ductwork is not provided with the dryer, and you
should obtain the necessary ductwork locally. The
end cap should have hinged dampers to prevent
backdraft when the dryer is not in use. Failure to
follow these instructions can result in fire or death.
IMPORTANT SAFETY INSTRUCTIONS
6
• The exhaust duct must be 4 in. (10.2 cm) in
diameter with no obstructions. The exhaust duct
should be kept as short as possible. Make sure to
clean any old ducts before installing your new
dryer. Failure to follow these instructions can result in
fire or death.
• Rigid or semi rigid metal ducting is recommended
for use between the dryer and the wall. In special
installations when it is impossible to make a
connection with the above recommendations, a
UL-listed flexible metal transition duct may be
used between the dryer and wall connection only.
The use of this ducting will affect drying time.
Failure to follow these instructions can result in fire or
death.
• DO NOT use sheet metal screws or other
fasteners which extend into the duct that could
catch lint and reduce the efficiency of the exhaust
system. Secure all joints with duct tape. For
complete details, follow the Installation Instructions.
Failure to follow these instructions can result in fire or
death.