2-9. Code list for Standby Cause
Code
Indication
Description
1
RC_STNBY /* Standby set by remote control */
2
E_CCKMVT /* Abnormal voltage of CCKM line detected */
5
OUT_OF_R "/* While a PC display is on, unspecified input continued long time. */"
6
NO_OPERT /* Off caused by no operation */
7
NO_SIGNA
/* Off caused by no signal */
8
PC_MODE1 /* Set by the PC power management mode 1 */
9
PC_MODE2 /* Set by the PC power management mode 2 */
A
SLEEP_TM /* Set by off timer */
B
E_NOMONI /* Incompatible monitor is connected to the AVC center. */
C
OFF_232C
/* Set by the command from RS232C */
E
AVC_TACT /* Set by the front switch at the AVC center */
F
BSBOOKED /* The pre-set time has passed since TV was turned on from standby by the BS timer. */
10
E_AVCFAN /* Fan failure at the AVC center */
11
E_BSSUBM /* Communication failure with the BS sub microcomputer (Not used) */
12
E_CVICIC
/* CVIC failure */
13
E_AVCTMP /* Abnormal temperature at the AVC center */
14
E_1BITAU
/* 1Bit-AMP failure */
15
E_MONIPW /* Monitor main power failure detected */
16
E_MONITR
/* Monitor problem detected */
17
E_FNLOCK /* Fan lock for North America */
40
/* Failure in Digital Standby */
33
LC-26D4U
LC-32D4U