Pin No.
Signal
I/O
23
P114
OUT
24
P115
OUT
25
P116
OUT
26
P117
OUT
27
AVSS
IN
28
ANI0
OUT
29-31
ANI1-ANI3
IN
32
ANI4
IN
33
ANI5
IN
34
ANI6
IN
35
ANI7
IN
36
VDD0
IN
37
AVREF
IN
38
P100
IN
39
P101
IN
40
VSS1
IN
41
P102
IN
42
P103
IN
43
P30
OUT
44-48
P31-P35
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to ANI7, P100, P101, P102
and P103 terminal while one of G4 line keys on key matrix is touched.
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to ANI6, ANI7, P100, P101,
P102 and P103 terminal while one of G3 line keys on key matrix is touched.
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to ANI6, ANI7, P100, P101,
P102 and P103 terminal while one of G2 line keys on key matrix is touched.
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to ANI7, P100, P101, P102
and P103 terminal while one of G1 line keys on key matrix is touched.
Connected to VC.
Terminal not used.
Terminal to change cooking input according to the Model.
By using the A/D converter contained in the LSI, DC voltage in accordance with the Model
in operation is applied to set up its cooking constant.
Used for initial balancing of the bridge circuit (absolute humidity sensor). This input is an
analog input terminal from the AH sensor circuit, and connected to the A/D converter built
into the LSI.
AH sensor input.
This input is an analog input terminal from the AH sensor circuit, and connected to the
A/D converter built into the LSI.
Input terminal to judge the model.
The signal out of P116 will be input into ANI6 through G2 line on key matrix. The LSI will
judge the model by this signal.
Signal coming from touch key.
When either G13 line on key matrix is touched, a corresponding signal out of P110 - P117
will be input into ANI7. When no key is touched, the signal is held at "H" level.
Power source voltage : GND(0V).
The power source voltage to drive LSI is input to VDD0 terminal.
A/D converter power source voltage : GND(0V).
The power source voltage to drive the A/D converter. Connected to GND.
Signal similar to ANI7.
When either G12 line on key matrix is touched, a corresponding signal will be input into
P100.
Signal similar to ANI7.
When either G11 line on key matrix is touched, a corresponding signal will be input into
P101.
Power source voltage : -5.0V.
The power source voltage to the drive LSI is input to VSS1 terminal. Connected to VC.
Signal similar to ANI7.
When either G10 line on key matrix is touched, a corresponding signal will be input into
P102.
Signal similar to ANI7.
When either G9 line on key matrix is touched, a corresponding signal will be input into
P103.
Terminal not used.
Used for initial balancing of the bridge circuit (absolute humidity sensor).