3-1-4. TRC Port (for optional kits TR-40, RJ-45) 3-1-5. AC output Interface 3-2. DC Input Side (Rear Panel) Introduction 3-2-1. Remote Port (RJ-11) 3-2-2. Remote Control Green Terminal 3-2-3. General instruction before DC Input ④ 3-2-4. Chassis Ground ③ 3-3. Maintenance 4.
1. Safety Instructions 1-1. General Safety Precautions Warning! Before using the Inverter, read the safety instructions. Do not expose the inverter to rain, snow, spray or dust. To reduce the risk of fire hazard, do not cover or obstruct the ventilation openings and do not install the inverter in a zero-clearance compartment.
Page 5
Do not operate near water or in excessive humidity. Do not open or disassemble the inverter, and warranty may be voided. The DC side connections should be firm and tight. Grounding: Reliable grounding should be maintained. ...
2. Functional Characteristics Introduction 2-1. System The unit is a highly reliable DC-AC inverter system, designed with advanced power electronic and microprocessor technology offering the following features: Pure sine wave output (THD < 5%) to operate Optional bypass relay(TR-40) function ...
Cooling Temperature & Load Controlled cooling Fan AC Transfer Function Accessories TR-40 (optional) Table 1. 450-0700-0 for Output 100/110/115/120 VAC Specification. Note: Voltage range:Please refer to Figure 1 Normal load Condition: Vin =12.5V/25V/50V, Vo=100/110/115/120 VAC 80% Full load (PF=1.0) ...
Page 9
Cooling Temperature & Load Controlled cooling Fan AC Transfer Function Accessories TR-40 (optional) Table 2. 450-0700-0 for Output 200/220/230/240 VAC Specification. Note: Voltage range:Please refer to Figure 1 Normal load Condition: Vin =12.5V/25V/50V, Vo=200/220/230/240 VAC 80% Full load (PF=1.0)
Specification Model No. Electrical 450-1000-0 Inquire Inquire Item Dimension(WxHxD) 200mm X 83mm X 372mm Weight 3.26 KG Cooling Temperature & Load Controlled cooling Fan AC Transfer Function Accessories TR-40 (optional) Table 3. SP-1000 for Output 100/110/115/120 VAC Specification. Note: Voltage range:Please refer to Figure 1 ...
Page 12
Specification Model No. Electrical Inquire Inquire Inquire Item Remote Controller CR-8 / CR-16 (optional) Panel Unit LED Indicator Red / Orange / Green LED Signal and Dry Contact Control By a relay Terminal Remote Control 6-port Green terminal (for inverter ON / OFF) Terminal Input Protection Over / Under Voltage, Reverse Polarity (Internal Fuse)
Specification Model No. Electrical 450-1500-0 Inquire Inquire Item Certified UL 458 Safety Standards ---- (UL only for GFCI receptacles) Safety & EMC EMC standards Certified FCC class B E-mark ---- Dimension(WxHxD) 248mm X 83mm X 421mm Weight 4.14 KG Cooling Temperature &...
Page 15
Specification Model No. Electrical Inquire Inquire Inquire Item Efficiency max. Output Short-Circuit 1 Sec Shutdown Characteristics Protection Output Waveform Pure Sine Wave (THD < 5%@ Normal Load) Remote Controller CR-8 / CR-16 (optional) Panel Unit LED Indicator Red / Orange / Green LED Signal and Dry Contact Control...
Specification Model No. Electrical 450-2000-0 Inquire Inquire Item Certified UL 458 Safety Standards ---- (UL only for GFCI receptacles) Safety & EMC EMC standards Certified FCC class B E-mark ---- Dimension(WxHxD) 248mm X 83mm X 443mm Weight 5.24 KG Cooling Temperature &...
Page 18
Specification Model No. Electrical Inquire Inquire Inquire Item Short-Circuit 1 Sec Shutdown Output Protection Characteristics Output Waveform Pure Sine Wave (THD < 5%@ Normal Load) Remote Controller CR-8 / CR-16 (optional) Panel Unit LED Indicator Red / Orange / Green LED Signal and Dry Contact Control...
Specification Model No. Electrical 450-3000-0 Inquire Inquire Item Safety Standards Certified UL 458 ---- Safety & EMC EMC standards Certified FCC class A E-mark ---- Dimension(WxHxD) 255mm X 158mm X 442mm Weight 8.2 KG Cooling Temperature & Load Controlled cooling Fan AC Transfer Function Accessories TR-40 (optional) Table 9.
Page 21
Specification Model No. Electrical Inquire Inquire Inquire Item Efficiency max. Output Short-Circuit 1 Sec Shutdown Characteristics Protection Output Waveform Pure Sine Wave (THD < 5%@ Normal Load) Remote Controller CR-8 / CR-16 (optional) Panel Unit LED Indicator Red / Orange / Green LED Signal and Dry Contact Control...
Specification Model No. Electrical Inquire Inquire Item Dimension(WxHxD) 255mm X 158mm X 462mm Weight 10 KG Cooling Temperature & Load Controlled cooling Fan AC Transfer Function Accessories TR-40 (optional) Table 11. SP-4000 for Output 100/110/115/120 VAC Specification. Note: Voltage range:Please refer to Figure 1 ...
Page 24
Specification Model No. Electrical Inquire Inquire Item Signal and Dry Contact Terminal By a relay Control Remote Control Terminal 6-port Green terminal (for inverter ON / OFF) Over / Under Voltage, Reverse Polarity Input Protection (Internal Fuse) Protection AC Output Protection Short-Circuit, Overload Over / Under Temperature Protection Others...
2-4. Mechanical Drawings Figure 3. 450-XXXX-X Series drawing (Top View) Figure 4. 450-XXXX-X Series drawing (AC output/Front View) Model A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) 450-0700-0 SP-1000 SP-1500 SP-2000 SP-3000 SP-4000 Table 13. 450-XXXX-X Series Dimension...
>62.0V Table 15. Input Voltage Level LED Indicator 3-1-2-2. Output Load Level to display AC Loads (PF=1) LED status Green Orange 450-0700-0 0 ~ 700 VA > 805 VA 700 ~ 805 VA SP-1000 0 ~ 1000 VA > 1150 VA...
LED status Status Recovery point Device startup Orange — process abnormal Under > 0 degree C Temperature Orange Fast Blink Protection (Heat sink temp. under -20 degree) Over Temperature < 60 degree C Orange Slow Protection (heat sink temperature) Blink (Heat sink temp.
User can use variable resistor (VR) to set the input and wake up power saving threshold according to the load condition, and the setting range shows below: Input Saving Power Saving Wake up (Min) Power (Min) 450-0700-0 <20 VA >40 VA 450-1000-0 <20 VA >40 VA 450-1500-0 <20 VA...
Table 24. 450-XXXX-X Series TRC Port : RJ-45. Figure 9. Wiring between 450-XXXX-X Series and TR-40 Note! The detail information. Please refer to TR-40 user manual. 3-1-5. AC output Interface 3-1-5-1. 450-0700/1000/1500/2000 AC output interface Socket Type Applicable Model 450-0700-0/450-1000-0 (100-120V) 450-1500-0/450-2000-0 (100-120V)
Page 32
Socket Type Applicable Model 450-0700-0/1000/1500/2000/3000 212/224/248 450-0700-0/1000/1500/2000 (100-120V) 450-0700-0/1000/1500/2000/3000 (200-240V) 450-3000-0 450-4000-0 450-0700-0/1000/1500/2000/3000 (200-240V) Table 25. 450-XXXX-X Series AC Socket vs. Model 3-1-5-2. SP-3000/4000 AC output interface Terminal Wire color Wire length / gauge Line (L) Black Within 16 feet / AWG#...
3-2. DC Input Side (Rear Panel) Introduction Figure 10. 450-0700-0/450-1000-0 Figure 11. 450-1500-0/450-2000-0 Figure 12. 450-3000-0/450-4000-0 450-0700-0 450-1000-0 450-1500-0 450-2000-0 450-3000-0 450-4000-0 Model Remote port (RJ11) ① Remote control green terminal ② Chassis ground ③ DC input connector ④ Table 27. Series DC input side introduction...
3-2-1. Remote Port (RJ-11) The 450-XXXX-X Series Inverter can be compatible with CR-8, and CR-16 remote control via RS-232 Communication. Before using the remote control, make sure the main switch on inverter must be at “ REMOTE” position. Signal Description ① Pin Number Reserved The same polarity as the battery negative...
Note! Fault conditions include Input under / over voltage, output short circuit / over load, over / under temperature. Caution! Please follow the following steps for the installation Before installing the inverter, make sure the main switch is at “OFF”...
4. Operation 4-1. Connection the DC cable Connect DC input terminals to 12V / 24V /48V battery or other DC power source [ + ] is positive, [ - ] is negative. Reverse polarity connection can blow the internal fuse and may damage the inverter permanently.
Figure 16. Battery cabling 4-2. Connecting the input power Before making the DC input side connections ④, the main switch must be at “OFF”. 4-3. Connecting the loads Calculate the total power consumption of the output load. Make sure that the total power consumption does not exceed the rated power.
450-XXXX-X Series Computer PIN Number Description PIN Number Description Not used Not used Not used Table 33. RS232 interface definition 5-2. RS232 Port Operating The following steps show the connection among inverter and computer. Step 1 Connect the RS232 port to the 450-XXXX-X Series unit on the front panel Step 2 Run the computer communication program...
5-3-2. Command format The following table shows the useful command to operate 450-XXXX-X Series. Function Command and description Format : Power <value> <value> can be one of the following. Turn ON / OFF “0” : Power OFF 450-XXXX-X Series “1” : Power ON Query the 450-XXXX-X Format: FRQ? Series output frequency...
6-2. Warranty All products of Kussmaul Electronics are warranted to be free of defects of material or workmanship. Liability is limited to repairing or replacing at our factory, without charge, any material or defects which become apparent in normal use within 2 years from the date the equipment was shipped.