1.0 INTRODUCTION .................................................................................................................................. 3
2.0 TESTING ................................................................................................................................................ 3
3.0 LIMITATIONS ...................................................................................................................................... 3
3.1 WARNINGS ........................................................................................................................................... 3
4.0 GLOSSARY ............................................................................................................................................ 4
5.0 SUMMARY OF OPERATION ............................................................................................................. 5
6.0 TELEPHONY CONTROL DIAGRAM ............................................................................................... 7
7.0 UNDERSTAND YOUR KEYPAD INDICATORS ............................................................................. 8
8.0 USER MENU SUMMARY DIAGRAM ............................................................................................... 9
9.0 USER PROGRAMMING SUMMARY TABLE ............................................................................... 10
10.0 ARMING THE SYSTEM .................................................................................................................. 13
10.1 AWAY ARMING .................................................................................................................. 13
10.2 DAY ARMING...................................................................................................................... 14
10.3 NIGHT ARMING .................................................................................................................. 14
10.4 FORCE ARMING ................................................................................................................. 15
10.5 HOLIDAY ARMING ............................................................................................................ 15
10.6 REMOTE CONTROL ARMING (OPTIONAL) ................................................................... 16
10.7 AUTO TIMER ARMING ...................................................................................................... 16
10.8 TELEPHONE REMOTE ARMING ...................................................................................... 17
11.0 DISARMING THE SYSTEM ........................................................................................................... 17
11.1 KEYPAD DISARMING ........................................................................................................ 17
11.2 REMOTE CONTROL DISARMING (OPTIONAL) ............................................................. 18
11.3 AUTO TIMER DISARMING ............................................................................................... 18
11.4 TELEPHONE REMOTE DISARMING................................................................................ 18
12.0 TURN ON/OFF HOME AUTOMATION POINT .......................................................................... 19
13.0 BYPASS ZONE .................................................................................................................................. 19
14.0 UN-BYPASS ZONE ........................................................................................................................... 20
15.0 VIEW SYSTEM TROUBLE ............................................................................................................. 20
16.0 EVENT VIEWER .............................................................................................................................. 21
17.0 CHIME MODE .................................................................................................................................. 22
18.0 VIEW ZONE VOCABULARY SETTING ...................................................................................... 22
19.0 VIEW HA POINT VOCABULARY SETTING .............................................................................. 23
20.0 EMERGENCY SITUATION ............................................................................................................ 23
21.0 PARTITIONING THE SYSTEM ..................................................................................................... 25
22.0 ARMING A PARTITIONED SYSTEM .......................................................................................... 25
22.1 AWAY ARMING 4 PARTITIONS SIMULTANEOUSLY .................................................. 25
22.2 AWAY ARMING EITHER 1 PARTITION .......................................................................... 26
22.3 FASTKEY AWAY ARMING EITHER 1 PARTITION ....................................................... 27
22.4 PARTITION DAY ARMING ................................................................................................ 28
22.5 PARTITION NIGHT ARMING ............................................................................................ 29
SmartBus P900-S32 Series USER MANUAL
1
V1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SmartBus P900-S32 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for BLUGUARD SmartBus P900-S32 Series

  • Page 1: Table Of Contents

    SmartBus P900-S32 Series USER MANUAL Contents 1.0 INTRODUCTION ..........................3 2.0 TESTING ..............................3 3.0 LIMITATIONS ............................3 3.1 WARNINGS ............................3 4.0 GLOSSARY ............................4 5.0 SUMMARY OF OPERATION ......................5 6.0 TELEPHONY CONTROL DIAGRAM ....................7 7.0 UNDERSTAND YOUR KEYPAD INDICATORS ................8 8.0 USER MENU SUMMARY DIAGRAM ....................
  • Page 2 SmartBus P900-S32 Series USER MANUAL 22.6 PARTITION FORCE ARMING ................... 29 22.7 PARTITION HOLIDAY ARMING ..................30 23.0 PARTITION DISARMING ......................30 24.0 USER CODE ............................31 25.0 USER PROGRAMMING MODE ....................32 25.1 ACCESS USER PROGRAMMING MODE ................. 32 25.2 EXIT USER PROGRAMMING MODE ................
  • Page 3: Introduction

    3.0 LIMITATIONS Even though BLUGUARD is an advanced security system, it does not 100% guarantee the protection against burglary, fire or other loses. Any alarm system whether commercial or residential is subjected to compromise or failure-to-warn for a variety of reasons.
  • Page 4: Glossary

    SmartBus P900-S32 Series USER MANUAL 4.0 GLOSSARY Alarm Memory This is the history of the most recent violations that occurred the last time when an alarm was triggered. To set the system into the ARMED mode. In this mode, a zone violation will activate an alarm condition.
  • Page 5: Summary Of Operation

    SmartBus P900-S32 Series USER MANUAL 5.0 SUMMARY OF OPERATION [4-digit User Code] + [#] System Disarm Intelligent Arming [4-digit User Code] + [#] Hold down [1] for 2 seconds Away Arm Hold down [2] for 2 seconds Day Arm Night Arm...
  • Page 6 SmartBus P900-S32 Series USER MANUAL SUMMARY OF OPERATION (CONT.) PARTITION SYSTEM ENABLED [4-digit User Code] + [#] + Intelligent Disarm [Partition 1] or [Partition 2] or [Partition 3] or [Partition 4] [4-digit User Code] + [#] + Intelligent Arming [Partition 1] or [Partition 2] or [Partition 3] or [Partition 4]...
  • Page 7: Telephony Control Diagram

    SmartBus P900-S32 Series USER MANUAL 6.0 TELEPHONY CONTROL DIAGRAM 6.0 TELEPHONY CONTROL DIAGRAM Call In to System: Call In to System: [Master System Dial Wait for 1 System Voice Report Phone Code] + welcome Answer note and Number voice menu...
  • Page 8: Understand Your Keypad Indicators

    SmartBus P900-S32 Series USER MANUAL 7.0 UNDERSTAND YOUR KEYPAD INDICATORS POWER INDICATOR ARMED INDICATOR SERVICE INDICATOR MEMORY INDICATOR MUTE KEYPAD The armed icon is SOUND The icon is displayed displayed when the The icon is displayed The indicator will be...
  • Page 9: User Menu Summary Diagram

    SmartBus P900-S32 Series USER MANUAL 8.0 USER MENU SUMMARY DIAGRAM Menu Zone Info Zone 1 – 32 vocabulary setting HA Point Info HA Point 1 – 32 vocabulary setting Messages Enter Code + [#] Play Message Erase This Message Erase All Message...
  • Page 10: User Programming Summary Table

    SmartBus P900-S32 Series USER MANUAL 9.0 USER PROGRAMMING SUMMARY TABLE Access User Programming Mode : [] + [MODE] + [4-digit Master Code] + [#] OR Access from LCD Menu Exit User Programming Mode : [] / Exit from LCD Menu...
  • Page 11 SmartBus P900-S32 Series USER MANUAL User Code 26 Key in [New User Code] + [#] [Re-confirm New User Code] + [#] User Code 27 Key in [New User Code] + [#] [Re-confirm New User Code] + [#] User Code 28...
  • Page 12 SmartBus P900-S32 Series USER MANUAL Remark: All programmed timer must be in 24-hour format e.g. 7 am = 07 00, 8 pm = 20 00. Program Reporting Telephone Numbers Tel No’s User Tel No: 1 Key in [16 digit Tel No.] + [#]...
  • Page 13: Arming The System

    SmartBus P900-S32 Series USER MANUAL 10.0 ARMING THE SYSTEM There are various options for arming the system Partition Arming Away Arming Day Arming Night Arming Force Arming Holiday Arming Remote Control Arming Timer Auto Arming Telephone Remote Arming For information on how to ARM Partition system, please refer to Partitioning The System at page 25 (Section 21.0).
  • Page 14: Day Arming

    SmartBus P900-S32 Series USER MANUAL 10.2 DAY ARMING (Press and hold down for 2 seconds) 1. This arming mode is ideal for DAY time arming with user still remains in the protected premises. 2. In this mode, the system will be armed instantly with certain preprogrammed, DAY STAY zones bypassed automatically.
  • Page 15: Force Arming

    SmartBus P900-S32 Series USER MANUAL 8. Any NIGHT STAY zones will be automatically bypassed which shown by flashing zone underline. 9. There is no ENTRY delay in this arming mode. Any violation on the active zones will trigger the system instantly.
  • Page 16: Remote Control Arming (Optional)

    SmartBus P900-S32 Series USER MANUAL 6. An EXIT delay countdown timer will be shown at the top right temporarily replace the clock and the keypad audible indicator will sound on and off for the duration of the EXIT delay. 7. Any bypassed zones will be shown by the flashing zone underline.
  • Page 17: Telephone Remote Arming

    SmartBus P900-S32 Series USER MANUAL 10.8 TELEPHONE REMOTE ARMING 1. Your system can be remotely ARM from outside the house through any normal DTMF telephone or GSM hand phone. 2. This arming mode will automatically turn to FORCE ARM mode when the user enter a correct Master Code through Telephone or hand phone.
  • Page 18: Remote Control Disarming (Optional)

    SmartBus P900-S32 Series USER MANUAL 8. If the icon is flashing upon entry there has been an intrusion. Call for assistance. The intruder may still be inside. 9. If no valid user code has been entered by the end of the ENTRY delay period, an ALARM condition will be registered and stored into the system MEMORY.
  • Page 19: Turn On/Off Home Automation Point

    SmartBus P900-S32 Series USER MANUAL 12.0 TURN ON/OFF HOME AUTOMATION POINT + [HA POINT NUMBERS] + [#] (Press and hold down for 2 seconds) (01 to 32) 1. Press and hold down key [5] for 2 seconds. 2. The screen will show “HA Info” and keypad audible indicator will sound 2 beeps.
  • Page 20: Un-Bypass Zone

    SmartBus P900-S32 Series USER MANUAL 7. Zones cannot be bypassed once the system is armed. 8. All bypassed zones will be automatically un-bypassed each time the system is disarmed and must be reapplied before the next arming. 14.0 UN-BYPASS ZONE...
  • Page 21: Event Viewer

    SmartBus P900-S32 Series USER MANUAL 3. The screen will show Trouble Messages and keypad audible indicator will sound 2 beeps. 4. The trouble occurred will be displayed. Press the [▼] key to check on all the troubles that need to be serviced.
  • Page 22: Chime Mode

    SmartBus P900-S32 Series USER MANUAL 17.0 CHIME MODE The chime mode allows user to monitor nominated zones while the system is disarmed. The audible indicator will sound briefly when the nominated zone is violated – the siren will NOT sound. If you wish to know there is someone enters or exits the front door, the keypad will beep once when the door is opened provided the zone is a chime zone.
  • Page 23: View Ha Point Vocabulary Setting

    SmartBus P900-S32 Series USER MANUAL 19.0 VIEW HA POINT VOCABULARY SETTING ▼ 1. Press [ ] key to the HA Point Info menu when system in normal mode. 2. Press [#] to access into zone info setting. Vocabulary settings are shown in the LCD.
  • Page 24 SmartBus P900-S32 Series USER MANUAL 5. Press this mode only in an emergency situation that requires response by emergency personnel. MEDICAL MODE [MODE] + [9] + [#] 1. The MEDICAL ALARM condition will be activated when press [MODE] + [9] + [#].
  • Page 25: Partitioning The System

    SmartBus P900-S32 Series USER MANUAL 21.0 PARTITIONING THE SYSTEM Depending on your needs, your installer can program your control panel to recognize and control 4 separate areas (Partition 1 to 4) by activating the system’s partitioning feature. User codes can also be programmed to ARM/DISARM one partition or more partitions simultaneously.
  • Page 26: Away Arming Either 1 Partition

    SmartBus P900-S32 Series USER MANUAL 6. An EXIT delay countdown timer will be shown at the top right temporarily replace the clock and the keypad audible indicator will sound on and off for the duration of the EXIT delay. 7. Any bypassed zones will be shown by the flashing zone underline.
  • Page 27: Fastkey Away Arming Either 1 Partition

    SmartBus P900-S32 Series USER MANUAL 5. Enter the partition number that you wish to arm followed by [#] key. 6. The icon will be displayed if Partition 1 is armed. 7. The icon will be displayed if Partition 2 is armed.
  • Page 28: Partition Day Arming

    SmartBus P900-S32 Series USER MANUAL 4. Select the partition number that you wish to arm followed by [#] key. 5. The partition number armed icon will be displayed if it is armed. 6. An EXIT delay countdown timer will be shown at the top right temporarily replace the clock and the keypad audible indicator will sound on and off for the duration of the EXIT delay.
  • Page 29: Partition Night Arming

    SmartBus P900-S32 Series USER MANUAL 22.5 PARTITION NIGHT ARMING [1 or 2 or 3 or 4] + [#] (Press and hold down for 2 seconds) 1. This arming mode is ideal for NIGHT time arming with user still remains in the protected premises.
  • Page 30: Partition Holiday Arming

    SmartBus P900-S32 Series USER MANUAL 8. User will be given an ENTRY delay time to disarm the system when enter the protected premises via ENTRY/EXIT zone. 22.7 PARTITION HOLIDAY ARMING [1 or 2 or 3 or 4] + [#] (Press and hold down for 2 seconds) 1.
  • Page 31: User Code

    SmartBus P900-S32 Series USER MANUAL 7. Select the partition number that you wish to disarm followed by [#] key. 8. The partition number armed icon will extinguish if it is disarmed. 9. If the partition number armed icon remain illuminated, an error has been made while entering the user code, press [] key and re-enter the user code.
  • Page 32: User Programming Mode

    SmartBus P900-S32 Series USER MANUAL 25.0 USER PROGRAMMING MODE 25.1 ACCESS USER PROGRAMMING MODE  ] + [MODE] + [USER MASTER CODE] + [#] 1. Ensure that the system is not ARMED. 2. Press the [] key to cancel any unintended entries.
  • Page 33: Program New And Changing Existing Duress Code

    SmartBus P900-S32 Series USER MANUAL 4. Enter the new 4-digit [MASTER CODE]. Example: 4567 followed by [#] key. 5. Re-enter the new 4-digit [MASTER CODE] followed by [#] key. 6. Use the [▲] key and [▼] key to scroll up and down to select other user code and repeat step 3.
  • Page 34: Erase User Or Duress Code

    SmartBus P900-S32 Series USER MANUAL 7. Press [] to exit user programming mode. 8. If the duress code is not used, please ensure the code is erased. 25.5 ERASE USER or DURESS CODE 1. Ensure that the system is in USER PROGRAMMING mode.
  • Page 35: Program System Timer

    SmartBus P900-S32 Series USER MANUAL 25.6 PROGRAM SYSTEM TIMER 1. Ensure that the system is in USER PROGRAMMING mode. 2. Press [▼] to scroll down to Clock. 3. Press [#] to select clock for system timer setting. 4. Enter the [CURRENT TIME] in 24-hour format. Example, 8:00pm is 20:00.
  • Page 36: To Erase Auto Arm Partition 1/2/3/4 Timer

    SmartBus P900-S32 Series USER MANUAL 6. Press [#] key to confirm the time. 7. Press [▼] to scroll down to program Arm P2 Timer, Arm P3 Timer and Arm P4 Timer.  8. Press [ ] to exit user programming mode.
  • Page 37: To Erase Auto Disarm Partition 1/2/3/4 Timer

    SmartBus P900-S32 Series USER MANUAL 3. Press [#] to access Timers menu. 4. Press [▼] to scroll down to Disarm P1 Tmr. 5. Press [#] to select Disarm P1 Tmr for auto disarm partition 1 timer. 6. Enter the [AUTO DISARM P1 TIMER] in 24-hour format. Example, 8:00pm is 20:00.
  • Page 38: Program Auto On Timer 1/2/3/4 For Home Automation

    SmartBus P900-S32 Series USER MANUAL 5. Press [#] to select Disarm P1 Tmr for auto disarm partition 1 timer. 6. Press the [F] key to set to 99:99 setting. 7. Press [#] key to erase previous [AUTO DISARM P1 TIMER] setting.
  • Page 39: To Erase Auto On Timer 1/2/3/4 For Home Automation

    SmartBus P900-S32 Series USER MANUAL  8. Press [ ] to exit user programming mode. 25.12 TO ERASE AUTO ON TIMER 1/2/3/4 FOR HOME AUTOMATION 1. Ensure that the system is in USER PROGRAMMING mode. 2. Press [▼] to scroll down to Timers.
  • Page 40: To Erase Auto Off Timer 1/2/3/4 For Home Automation

    SmartBus P900-S32 Series USER MANUAL 4. Press [▼] to scroll down to OFF HA Tmr 1 and press [#] for auto off timer 1. 5. Enter the [AUTO OFF TIMER 1] in 24-hour format. Example, 8:00pm is 20:00. 6. Press [#] key to confirm the time.
  • Page 41: Program Personal Telephone Number 1/2/3/4

    SmartBus P900-S32 Series USER MANUAL 25.15 PROGRAM PERSONAL TELEPHONE NUMBER 1/2/3/4 1. Ensure that the system is in USER PROGRAMMING mode. 2. Press [▼] to scroll down to Tel Nos. 3. Press [#] to access Tel Nos menu. 4. Press [#] to select User Tel No1.
  • Page 42: Program Gsm Telephone Number 1/2/3/4

    SmartBus P900-S32 Series USER MANUAL 3. Press [#] to access Tel Nos menu. 4. Press [#] to select User Tel No1. 5. Press the [F] key to erase the setting. 6. Press [#] key to erase previous [PERSONAL TELEPHONE NUMBER 1].
  • Page 43: To Erase Gsm Telephone Number 1/2/3/4

    SmartBus P900-S32 Series USER MANUAL 6. Press the [F] key to temporary erase setting or wrong keyed in numbers. 7. Button “▲” on the keypad is representing a “PAUSE” key of 5 seconds duration.  8. Button “▼” on the keypad is representing a “...
  • Page 44: Program System Date

    SmartBus P900-S32 Series USER MANUAL 25.19 PROGRAM SYSTEM DATE 1. Ensure that the system is in USER PROGRAMMING mode. 2. Press [▼] to scroll down to Date. 3. Press [#] to select Date. 4. Enter the [DATE] in DDMMYY format. Example 22 February 2010 is 220210.
  • Page 45: Cms Test (Manual Test)

    SmartBus P900-S32 Series USER MANUAL 26.2 CMS TEST (Manual Test) 1. CMS Test allows on-site testing of CMS Reporting. 2. Press [MODE] + [2] + [#] or from MENU, i.e, (Menu  System Test  CMS Test). 3. A CMS testing code will be sent to the central monitoring station.
  • Page 46: Intercom

    SmartBus P900-S32 Series USER MANUAL 27.0 INTERCOM Keypads can be used to intercom, provided more than one keypad installed. 1. Press and hold intercom button [ ] more than 2s: 2. Start talking to the keypad microphone and your voice will be heard at other keypads.
  • Page 47 SmartBus P900-S32 Series USER MANUAL To leave voice message 1. Press and hold recording button [ ] more than 2s: 2. Press the user number (from 1 to 8 only). Leave a voice message (up to 45 seconds) after the beep sound by talking to the keypad microphone, and press # key to end: 3.
  • Page 48: Page Switching

    SmartBus P900-S32 Series USER MANUAL 29.0 PAGE SWITCHING S32 LCD Keypad can display up to 32 zones status and it can be viewed up to 16 zones at a time. Page switching is divided into 2 pages where users are required to select which page to be displayed.
  • Page 49: System Information

    SmartBus P900-S32 Series USER MANUAL 30.0 SYSTEM INFORMATION SECURITY ZONE INFORMATION Zone No. Partition Zone Type Location _____________________ Central Monitoring Station Number _____________________ Central Monitoring Station Account Number : Servicing Installer company : _____________________________ Contact person : _____________________________ Contact number...
  • Page 50: System Setting

    SmartBus P900-S32 Series USER MANUAL 31.0 SYSTEM SETTING Partition 1 Entry Time Partition 1 : _____________________________ seconds Exit Time Partition 1 : _____________________________ seconds Siren Cut-Off Time for Partition 1 : _____________________________ minutes Partition 2 Entry Time Partition 2 : _____________________________ seconds...

Table of Contents