Mechanical Disassemblies
■ Flat Cable Removal
This set is used 3 kinds of connector for flat cable. For removal of cable, refer as below not to damage.
Type A
Cable
For removal of flat cable, lift up hook of
both sides.
For insert and fixing, hold down hook
after inserting the flat cable.
■ For Gasket
The gasket (like brown tape) is provided to prevent exposure of interference for other radio and television receptions.
The gasket should be replaced on previous positions after servicing.
See Fig.9 for example.
Type B
Cable
For removal of flat cable, slide hook of
both sides.
For insert and fixing, slide hook to pre-
vious position after inserting the flat
cable.
-14-
Type C
Cable
For removal of flat cable, pull off only.
For fixing , insert into socket.