Sanyo VPC-FH1BK Service Manual page 22

Hide thumbs Also See for VPC-FH1BK:
Table of Contents

Advertisement

3. Double-click on the DscCalDi.exe.
4. Input "32" in the Cal Mode, and click Ok at the right side.
5. Click the OK.
6. Input "30" in the Cal Mode, and click Ok at the right side.
7. Click the OK.
Dsc Calibration
OK
Copy
Cal Mode Results :
IRIS_LG: 12535
IRIS_LG_R1: 701
IRIS_LG_R2: 982
IR_TEMP_AD=345
IRIS_PWM1=200,166
IRIS_PWM2=143,119
IRIS_PWM3=108,98
IRIS_PWM4=89,82
IRIS_PWM5=77,72
IRIS_PWM6=68,65
Adjustment value determination is effectuated using the "MS",
" M S _ M " , " M S _ C " , " M S _ C 2 " , " M S _ C 3 " , " M S _ C 4 " ,
"IRIS_PWM1", "IRIS_PWM2", "IRIS_PWM3", "IRIS_PWM4",
" I R I S _ P W M 5 " , " I R I S _ P W M 6 " , " I R _ T E M P _ A D " a n d
"IRIS_LG_R2" values. If
MS = ms1, ms2
MS_M = ms3, ms4
MS_C = ms5, ms6
MS_C2 = ms7, ms8
MS_C3 = ms9, ms10
MS_C4 = ms11, ms12
IRIS_PWM1 = s1, s2
IRIS_PWM2 = s3, s4
IRIS_PWM3 = s5, s6
IRIS_PWM4 = s7, s8
IRIS_PWM5 = s9, s10
IRIS_PWM6 = s11, s12
IR_TEMP_AD = itad
IRIS_LG_R2 = iris_lg2
the adjustment values fulfill the conditions below, they are
determined as within specifications.
Adjustment value determination
2000<=ms1<=6500, 100<=ms2<=4100,
1800<=ms3<=5800, 1500<=ms4<=5500,
1000<=ms5<=5000, 800<=ms6<=4800,
700<=ms7<=4700, 500<=ms8<=4500,
450<=ms9<=4450, 400<=ms10<=4400,
300<=ms11<=4300, 200<=ms12<=4200
0<=s1<=255, 0<=s2<=255, 0<=s3<=255, 0<=s4<=255,
0<=s5<=255, 0<=s6<=255, 0<=s7<=255, 0<=s8<=255,
0<=s9<=255, 0<=s10<=255, 0<=s11<=255, 0<=s12<=255
ms2<ms12<ms11<ms10<ms9<ms8<ms7<ms6<ms5<ms4<ms3<ms1
s1>s2>s3>s4>s5>s6>s7>s8>s9>s10>s11>s12
250<=itad<=893
900<=iris_lg2<=1100
Adjustment values other than the above are irrelevant.
x
Dsc Calibration
Copy
Cal Mode Results :
MS=4580,100
MS_M=3706,3349
MS_C=2796,800
MS_C2=700,500
MS_C3=450,400
MS_C4=300,200
5. WB Adjustment
x
OK
Preparation:
POWER switch: ON
Setting of pattern box:
Color temperature: 3100 ± 20 (K)
Luminance: 900 ± 20 (cd/m
Adjusting method:
1. Set a distance of 0.5-1.0 cm between the pattern box and
the camera. (Do not enter any light.)
2. Double-click on the DscCalDi.exe.
3. Input "22" in the Cal Mode, and click Ok at the right side.
4. Click the OK.
5. Input "25" in the Cal Mode, and click Ok at the right side.
6. Click the OK.
Dsc Calibration
Cal Mode Results:
WB=342,522,623
CHECK=129,127,127
Adjustment value determination is effectuated using the
"CHECK" and "CHECK_ND" values. If
CHECK= wc0, wc1, wc2
CHECK_ND= wnc0, wnc1, wnc2
the adjustment values fulfill the conditions below, they are de-
termined as within specifications.
– 22 –
Camera
Pattern box
(color viewer)
2
)
x
Dsc Calibration
OK
Copy
Cal Mode Results:
WB_ND=0,0,0
FLAG_FS_ADJ=17
CHECK_ND=129,129,0
x
OK
Copy