2.4

CU-4E23PBE

Indoor Unit Combination
Power Source
Cooling Operation
Heating Operation
Maximum Current
Starting Current
Circuit Breaker Capacity
Dimension
Net Weight
Connection Cable
Pipe Length Range (1 room)
Maximum Pipe Length (Total Room)
Refrigerant Pipe Diameter
Compressor
Air Circulation
Fan Speed
Heat Exchanger
Air Volume
Refrigerant Control Device
Refrigerant Oil
Refrigerant (R410A)
Item
Capacity
Running Current
Electrical
Power Input
Data
EER
Sound Pressure Level
Noise
Sound Power Level
Capacity
Running Current
Electrical
Power Input
Data
COP
Sound Pressure Level
Noise
Sound Power Level
Height
Width
Depth
Liquid Side
Gas Side
Type
Motor Type
Rated Output
Type
Motor Type
Rated Output
High (Cooling / Heating)
Type
Tube Material
Fin Material
Row / Stage
FPI
High (Cooling / Heating)
Unit
1.6kW + 1.6kW + 1.6kW + 2.0kW
1 Phase, 230V, 50Hz (Power supply from outdoor unit)
kW
BTU/h
A
kW
W/W
dB-A (H/L)
dB (H/L)
kW
BTU/h
A
kW
W/W
dB-A (H/L)
dB (H/L)
A
A
A
mm
mm
mm
kg
m
m
mm (inch)
mm (inch)
W
W
RPM
Plate fin configuration forced draft type
3
m
/min
g
11
OUTDOOR UNIT
6.8 (1.9 ~ 8.8)
23200 (6480 ~ 30000)
7.5
1.68 (0.34 ~ 2.47)
4.05 (5.59 ~ 3.56)
48 / -
62 / -
8.5 (3.0 ~ 10.6)
29000 (10200 ~ 36100)
8.8
1.90 (0.58 ~ 2.60)
4.47 (5.17 ~ 4.08)
49 / -
63 / -
15.6
8.8
20
795
875 (+95)
320
72
2
3 + 1 (Earth) ø1.5 mm
3 ~ 25
60
6.35 (1/4)
9.52 (3/8) (E21:12.7(1/2))
Hermetic Motor / Rotary
Brushless (4-poles)
1.30k
Propeller Fan
DC Motor (8-poles)
60
600 / 620
Copper
Aluminum (Pre Coat)
2 / 36
19
42.5 / 44.1
Expansion Valve
FV50S
2.64k

Hide quick links: