Sanyo SBM-20 Service Manual page 24

Automatic
Hide thumbs Also See for SBM-20:
Table of Contents

Advertisement

Symptom
Procedure
Inspection
Cause
Countermeasure
C. Bread can not
I) Check motor and its
be made.
wiring.
Start
(Cannot
be
Motor failure
Replace motor
kneaded)
YES
Poor
connec-
Repair wiring
tion ofCN103
2) Measure
control
NO
board voltage.
. Control
board
Replace
con-
(While
motor
is
failure
trot board
operating)
YES
@-@
Approx. 5V
Power
board
Replace power
*
failure
board
D- :&::dan
not
1) Measure
sensor re-
(No baking, or
sistance.
Start
over-baking)
YES
* Sensor failure
Replace
sen-
sor
NO
2) Check heater and its
Heater failure
wiring.
Replace heater
YES
Poor connec-
Repair wiring
tion of CNI 02
3) Measure
control
board voltage.
NO
Control
board
Replace
con-
" failure
(While
heater
is
trol board
operating)
@-@)
Approx. 5V
YES
Power
board
Replace power
" failure
board
E. Buzzer is not
1) Measure
control
sounded.
board voltage.
Start
(While
buzzer
is
sounding)
NO
@-@
Approx. 5V
* Control
board
Replace
con-
failure
trol board
YES
e Power
board
Replace power
failure
board
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents