Connection Warnings; User Guide - INFOSEC 5000 VA User Manual

Table of Contents

Advertisement

Available languages

Available languages

1 . S A F E T Y I N S T R U C T I O N S – S e c u r i t y
IMPORTANT!
CAUTION: Before performing the procedures in this document, read and follow the safety instructions and
important regulatory information in your Safety, Environmental, and Regulatory Information document.
This manual contains important instructions that you should follow during installation and maintenance of the UPS and
batteries. Please read all instructions before operating the equipment and save this manual for future reference.
1.1 UPS Location Warnings:
Install your UPS indoors, away from excess moisture or heat, direct sunlight, dust and conductive contaminants.
Install your UPS in a structurally sound area. Your UPS is extremely heavy; take care when moving and lifting the unit.
Only operate your UPS at indoor temperatures between 32°F and 104°F (between 0° C and 40° C).
Leave adequate space around all sides of the UPS for proper ventilation.
Do not install the UPS near magnetic storage media, as this may result in data corruption.
Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner will seriously inhibit
the unit's internal cooling, eventually causing product damage not covered under warranty.

1.2 Connection Warnings:

There is no standard feedback protection inside, please isolate the UPS before working according to this circuit.
The following table lists AC contactor that can be used as back feed protection devices.
Table 1:
Module type
5 K
6 K
8 K
10 K
This UPS should be connected with TN earthing system
The power supply for this unit must be single-phase rated in accordance with the equipment nameplate. It also must
be suitably grounded
Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause
the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not
use this equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide.
Connect your UPS power module's grounding terminal to a grounding electrode conductor.
The UPS is connected to a DC energy source (battery). The output terminals may be live when the UPS is not
connected to an AC supply.
2
Manufacturer
Tianshui 213 Electrical Apparatus Co.,Ltd
LS Industrial systems Co.,Ltd.
Tianshui 213 Electrical Apparatus Co.,Ltd
LS Industrial systems Co.,Ltd.
Tianshui 213 Electrical Apparatus Co.,Ltd
Tianshui 213 Electrical Apparatus Co.,Ltd
INFOSEC UPS SYSTEM - 4, rue de la Rigotière - 44700 Orvault - FRANCE - www.infosec-ups.com
Hot Line – Tel + 33 (0)2 40 76 15 82 - Fax + 33 (0)2 40 94 29 51 - hotline@infosec.fr – 05 13 AA 59 206 14

User guide

Type
GSC1(CJX4-d)-4011
GMC(D)-32
GSC1(CJX4-d)-4011
GMC(D)-32
GSC1(CJX4-d)-6511
GSC1(CJX4-d)-6511
Rating
220Vac,40A
600Vac,45A
220Vac,40A
600Vac,45A
220Vac,65A
220Vac,65A

Advertisement

Table of Contents
loading

This manual is also suitable for:

8000 va6000 va10000 va

Table of Contents