Download Print this page

Roller Grill RFG 12 Instruction Manual And Installation Instructions

Gas fryer

Advertisement

Quick Links

INSTRUCTION MANUAL FOR USE AND INSTALLATION
GAS FRYER
RFG 12
Made in France
Made in France
Made in France
Made in France
December 2014

Advertisement

loading
Need help?

Need help?

Do you have a question about the RFG 12 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Roller Grill RFG 12

  • Page 1 INSTRUCTION MANUAL FOR USE AND INSTALLATION GAS FRYER RFG 12 Made in France Made in France Made in France Made in France December 2014...
  • Page 2: Table Of Contents

    SOMMAIRE 1. Security instructions 2. Contents of cardboard packaging 3. Conformity of use 4. Way of functioning 5. Functioning / Manipulation 5-6-7 6. Cleaning and maintenance 7. Technical specifications Appendix: part list and exploded view 10-11...
  • Page 3: Security Instructions

    GAS FRYER RFG 12 Congratulations for the acquisition of this upmarket appliance made in France. You chose an appliance which alloys the best technical qualities with a big user-friendliness. We wish you the biggest contentment 1. SECURITY INSTRUCTIONS Please respect these instructions scrupulously to avoid any risk of fire, scald or other wounds and damage.
  • Page 4: Contents Of Cardboard Packaging

    - A set of natural gas injectors - The present note Piezo power-on knob Thermostatic tap, power regulation Draining tap See the exploded of the RFG 12 at the end of the document 3. CONFORMITY OF USE Use the machine only to cook some food...
  • Page 5: Way Of Functioning

    4. WAY OF FUNCTIONING This modular high power gas fryer has a capacity of 10L for 2,5 Kgs fresh or frozen French fries, doughnuts, fish etc. The drawn and lightly tilted tank in only one piece is especially made for the direct flow of the oil without rest of oil in the tank.
  • Page 6 Check the supply pressure using a manometer when all the burners are lit. It must be equal to the indications on the rating plate. The fresh air flow required for combustion air supply is: - RFG 12 13m3/h General conditions of installation The installation and maintenance of the appliance must be carried out in compliance...
  • Page 7 Gas category table, according to the country of destination of the appliance Country of destination Category Pressures Diameter of in- jector FR/BE II2E+3+ G20/G25 20/25 G30/G31 28-30/37 LU/DE II2E3B/P G30/G31 II2E3+ G30/G31 28-30/37 AT/CH/CY/DK/EE/FI/ II2H3B/P HR/LT/LV/NO/RO/SE/ G30/G31 SI/SK/TR II2E3P HR/HO II2H3P CH/CY/CZ/ES/GB/GR/ II2H3+...
  • Page 8: Cleaning And Maintenance

    - Press and turn the thermostatic tap (n°3 on picture) in front of star position. - Keep pressed and turn on the pilot light thanks to the piezo (n°1 on picture) to light the burner. - Keep the control knob pressed for about 15 seconds. And turn the knob (n°3 on picture) on position 8 to turn on the burner - Turn the power control knob (n°3 on picture) to the desired position.
  • Page 9: Technical Specifications

    7. TECHNICAL SPECIFICATIONS Model RFG 12 Power 7 kW Outside dimensions 400x700x565 Volume 10 L Nb of burner Weight 25 kg Maximum charges 2.5 Kg 8. GUARANTEE Conditions of guarantee The guarantee applicable to any device is the commercial guarantee of the distrib- utor or the retailer.
  • Page 10: Appendix: Part List And Exploded View

    Nomenclature Friteuse RFG 12 Spare parts Fryer RFG 12...