11.7 TONEARM STOPPING POSITION
1. Set SIZE lever to 25 position.
2. At time of auto lead-in, when plate D has
contacted plate M, turn adjusting screw so that
dimension A shown in Fig. 24 becomes 2mm.
s 0
Adiust screw
Fis.24
11.8 REPEAT BUTTON LOCK
1. Set for stop mode.
2. When REPEAT button is pressed, tum adjusting
screw so that plate A locks the microswitch in
the ON position (Fig. 25).
Adiust screw
F i g.25
1 1.9 PLA T TE R HEIGHT
1. Adjust 4 screws so that spacing between platter
and cabinet becomes 2.5mm (Fig. 26).
Adiust screw
,riff i
,
E'.6