Has Master PIN Code Privileges
This option allows the user to access all menu commands listed in
the user guide. PIN codes that are not assigned as a master PIN
are restricted to which menu commands are available.
Expire PIN Code
This option restricts the user to turn on/off the system for the
number of days (0 = Unlimited/ 1 to 255 days) programmed
programmed by the installer.
Is Arm Only Code
This option restricts the user to only turn an area on. The user has
no access to turn an area off or reset an alarm.
Can Bypass Zones
This option allows the user to manually bypass and un-bypass
zones.
Can Auto Bypass Zones
This option allows the user to automatically bypass faulted zones
upon turning the area on. The keypad will prompt the user to
bypass each faulted zone.
Send 'Open' / 'Close' Reports
This option allows the Vision control panel to send 'Open' reports
when a user turns off (disarm) an area. When the user turns on
(arms) an area, the Vision control panel will send a 'Close' report.
Access > User Properties >

Timer Group

Reserved
Access > User Properties >

Access Assignment

Reserved
Issue 1.02

AREAS

The Vision-64 control panel has the ability to be partitioned up
to 8 individual areas. This section outlines various commands that
control individual areas.
Areas > Commands >

Area Status

This menu allows users the ability view the area status of the
current area or the status of a different area. This menu is only
available via a keypad who's corresponding area is turned off.
1.
Enter [MENU] + [2] + [0] + [0].
A list of available areas will display on the keypad.
2.
Use the [↑] and [↓] keys to select the area that you want
to view the status information, then press [OK] to select.
Alternatively, you can enter the area number, then press
[OK].
The keypad will display the area status information.
MENU 1-4-4
If the area is turned All On, the keypad will display:
MENU 1-4-5
If the area is turned Part On, the keypad will display:
3.
To exit, press [OK].
Vision-64 User Guide
A001 Main Office
A002 Production
A003 Warehouse
PRESS
, OK or MENU

Main Office A001
Disarmed
Press OK or MENU
Main Office A001
Armed All On
Main Office A001
Armed Part On
Copyright © 2002-2004 Digflex Pty Ltd
13
MENU 2-0-0