The Martin logo, the RUSH by Martin logo, the RUSH by Martin name, the Martin name and all other trademarks in this document pertaining to services or products by Martin Professional or its affiliates and subsidiaries are trademarks owned or licensed by Martin Professional or its affiliates or subsidiaries.
Table of contents Safety information ..................... 4 Lamp safety ....................7 Introduction ..................... 10 Before using the product for the first time ........... 10 Physical installation ..................11 Fastening the fixture to a flat surface ............11 Mounting the fixture on a truss ..............12 Securing with a safety cable ...............
(see www.martin.com/distributors for details) or call the Martin™ 24-hour service hotline on +45 8740 0000, or in the USA on 1-888-tech-180. Respect all locally applicable laws, codes and regulations when installing, operating or servicing the fixture. RUSH Wizard User Manual...
Page 5
It may also cause damage or malfunction and it may void your product warranty. Install, operate and service RUSH by Martin™ products only as directed in their user manuals, or you may create a safety hazard or cause damage that is not covered by product warranties.
Page 6
MAINS IN input socket, but do not link more than: • six (6) RUSH Wizard fixtures in total at 100-120 V, or • twelve (12) RUSH Wizard fixtures in total at 200-240 V. The voltage and frequency at the MAINS OUT socket are the same as the voltage and frequency applied to the MAINS IN socket.
If the quartz envelope of a discharge lamp is broken, the lamp releases a small quantity of mercury and other toxic gases. If a discharge lamp explodes in a confined area, evacuate the area and ventilate it thoroughly. Wear nitrite gloves when handling a RUSH Wizard User Manual...
Page 8
If the fixture is installed in a location where it may cause injury or damage if it falls, install as directed in this manual a secondary attachment such as a safety cable that will hold the fixture if a primary attachment fails. The secondary attachment RUSH Wizard User Manual...
Page 9
Do not attempt to use a fixture that is obviously damaged. Do not modify the fixture or install other than genuine RUSH by Martin™ parts. Refer any service operation not described in this manual to a qualified technician.
Introduction The RUSH Wizard™ is a multi-beam effect light that creates intense long- throw narrow beams with multi-color and gobo pattern projections and features electronic dimming and a strobe effect. The Wizard features a show mode with preprogrammed macros that allow fast deployment of a full range of effects.
8.8 minimum steel M12 bolt and self-locking nut (or as recommended by the clamp manufacturer) fastened through one of the clamp holes in the fixture’s folding bracket. You can use any of the holes RUSH Wizard User Manual...
See illustration above. Attach the safety cable to the attachment point (arrowed) on the fixture and to a secure anchoring point (securely anchored eyebolt or truss chord, for example). RUSH Wizard User Manual...
Brown EU system The fixture has an auto-ranging power supply that accepts AC mains power at 100-240 V at 50/60 Hz. Do not apply AC mains power at any other voltage or frequency to the fixture. RUSH Wizard User Manual...
Using 14 AWG or 1.5 mm cables from Martin™, you can link: • Maximum six (6) RUSH Wizard fixtures to power in a chain at 100-120 V, • Maximum twelve (12) RUSH Wizard fixtures to power in a chain at 200- 240 V.
• Return to the previous level of the menu MENU structure, or • Press and hold to exit menus completely DOWN Go down a menu branch Go up a menu branch ENTER Confirm the selected function RUSH Wizard User Manual...
Page 17
The T 6.3A fixture fuse F1 is located in a fuseholder next to the AC mains power connectors. 9 - Safety cable attachment point Loop a secondary attachment such as an approved safety cable that is rated for the weight of the fixture through this attachment. RUSH Wizard User Manual...
If a splitter is used, terminate each branch of the link. Connecting the DMX data link To connect the fixture to data: 1. Connect the DMX data output from the controller to the first fixture’s male XLR DMX input connector. RUSH Wizard User Manual...
Page 19
2. Connect the first fixture’s DMX output to the DMX input of the next fixture and continue connecting fixtures output to input. Terminate the last fixture on the link with a DMX termination plug. RUSH Wizard User Manual...
Two fixtures of the same type may share the same address, if identical behavior is desired. Address sharing can be useful for diagnostic purposes and symmetric control, particularly when combined with the inverse pan and tilt options. RUSH Wizard User Manual...
DMX signal in the DMX STATE menu (see ‘Master/slave’ on page 23). 3. Set the first fixture in the chain to run a standalone show using its SHOW MODE menu (see ‘Show mode’ above). This fixture will now act as the master. RUSH Wizard User Manual...
Page 22
3. Press ENTER to set (or press MENU to exit without making a change). Sound activation microphone sensitivity To adjust the sensitivity of the sound activation microphone: 1. Select SOUND SENSE and press ENTER to confirm. RUSH Wizard User Manual...
To set the fixture to return to the last state it was in when was is not receiving a DMX signal: 1. Select DMX STATE and press ENTER to confirm. 2. Use the DOWN and UP buttons to select LAST STATE. RUSH Wizard User Manual...
1. Select AUTO TEST and press ENTER to confirm. The fixture will run the auto test routine. 2. Press MENU to stop the test and exit. Lamp settings Lamp On/Off To manually power the lamp on or off: 1. Select LAMP ON/OFF and press ENTER to confirm. RUSH Wizard User Manual...
Fixture operating hours counter To see how many hours the fixture has been in use since manufacture: 1. Select FIXTURE HOURS and press ENTER to display the number of hours of use. 2. Press MENU to exit. RUSH Wizard User Manual...
Page 26
1. Select DEFAULTS and press ENTER to confirm. 2. Use the DOWN and UP buttons to select YES (return to default settings) or NO. 3. Press ENTER to confirm (or press MENU to exit without making a change). RUSH Wizard User Manual...
The fixture resets each time it is powered on, but you can force it to reset at any time. To force a reset: 1. Select RESET 2. Press ENTER to confirm (or press MENU to exit without resetting). RUSH Wizard User Manual...
You can project any gobo statically or rotate the wheel continuously clockwise or counter-clockwise with variable speed. A random gobo function is available. In the control menu you can set the fixture to automatically black out during gobo changes. RUSH Wizard User Manual...
The internal multi-facetted reflector dish can be shaken or rotated to give a dynamic array of multiple beams. • The mirror drum can be shaken or rotated to give continuous tilt: the array of rotating beams will appear to spin past in a continuous stream. RUSH Wizard User Manual...
Reset the fixture. • Power the lamp on or off. • Enable or disable Auto blackout, in which the fixture blacks out momentarily during pan, gobo, and color changes. • Illuminate or turn off the control panel display. RUSH Wizard User Manual...
If one or more of these factors is present, inspect fixtures within their first 100 hours of operation to see whether cleaning is necessary. Check again at frequent intervals. This procedure will allow you to assess cleaning RUSH Wizard User Manual...
Page 32
If in doubt, consult your RUSH by Martin dealer about a suitable maintenance schedule. Use gentle pressure only when cleaning, and work in a clean, well-lit area. Do not use any product that contains solvents or abrasives, as these can cause surface damage.
Page 33
Note the position of the lamp and the lamp wiring. Holding the spade connectors, not the wires, pull the two spade connectors off the terminals on the back of the lamp. RUSH Wizard User Manual...
Page 34
RESET TIME. Press ENTER to reset the lamp hours counter to zero, then press and hold MENU to exit. 11. Send the old lamp to a waste disposal center that can correctly deal with used discharge lamps. RUSH Wizard User Manual...
1. Disconnect the fixture from power and allow it to cool for at least 30 minutes. 2. Unscrew the cap of the fuseholder and remove the fuse. Replace with a fuse of the same size and rating only. 3. Reinstall the fuseholder cap before reapplying power. RUSH Wizard User Manual...
Dark Blue White 61-74 White White Red 76-89 Red Orange 91-104 Orange Orange Green 106-119 120-158 Green Color wheel: stepped scrolling 159 -160 Open 161-163 Blue 164-166 Magenta 167-169 Yellow 170-172 Dark Blue 173-175 White RUSH Wizard User Manual...
Page 38
CW rotation, slow fast 128-190 191-192 Stop (stops at current position) CCW rotation, slow fast 193-255 Mirror drum swivel (pan) Fade Position, min. max. 0-120 121-127 Shake, slow fast Random positions, slow fast 128-191 RUSH Wizard User Manual...
Page 39
31-35 FX 5 36-40 FX 6 41-45 FX 7 46-50 FX 8 51-55 FX 9 56-60 FX 10 61-65 FX 11 66-70 FX 12 71-75 FX 13 76-80 FX 14 81-85 FX 15 86-90 FX 16 RUSH Wizard User Manual...
Page 40
Music trig all 136-140 Music trig movement 141-145 Music trig color 146-150 Music trig gobo 151-155 Music trig color and gobo 156-160 Random FX 161-255 No function FX speed Fade 0-10 Stop FX speed, slow fast 11-255 RUSH Wizard User Manual...
Display backlight goes into sleep Back Light mode if control panel not used Display backlight constantly on Pan Reverse Yes/No Invert pan direction Auto Test Automatic test of all effects Lamp On/Off On/Off Manually power lamp on or off RUSH Wizard User Manual...
Page 42
Fixture operating hour counter Exit Exit lamp hour counter Lamp On Hours Reset Time Reset lamp hour counter to zero Firmware Display currently installed fixture Version software version Return fixture to factory default Defaults Yes/No settings Reset Reset fixture RUSH Wizard User Manual...
Fixture not in show Set fixture to show mode in mode. DMX state menu. Sound activation Enable. disabled. Sound activation Adjust microphone microphone sensitivity sensitivity. too low for music source. Fixture receiving DMX. Stop DMX signal. RUSH Wizard User Manual...
Page 44
Check that all devices on the DMX link use standard DMX polarity. Try to control the fixture with another DMX control device. Move or shield link if it is close to an unshielded high-voltage installation. RUSH Wizard User Manual...
Control options .......... DMX, standalone, master/slave DMX channels ..................10 Stand-alone trigger options ........... Music trig, auto trig Setting and addressing ....... Control panel with LCD display DMX compliance ............USITT DMX512/1990 Construction Color ....................Black RUSH Wizard User Manual...
Page 46
........EN 61000-3-2, EN 61000-3-3, EN 61547 US safety ..................UL 1573 US EMC..............FCC Part 15 Class A Canadian safety ....CSA C22.2 No. E598-2-17 (CSA E60598-1) Canadian EMC ............... ICES-003 Class A Australia/NZ ................C-TICK N4241 RUSH Wizard User Manual...
(Waste Electrical and Electronic Equipment), where applicable. Help preserve the environment! Ensure that this product is recycled at the end of its life. Your supplier can give details of local arrangements for the disposal of RUSH by Martin products. RUSH Wizard User Manual...