Mitsubishi Electric 9700 Series Owner Technical Manual page 60

Mitsubishi uninterruptible power system technical manual
Hide thumbs Also See for 9700 Series:
Table of Contents

Advertisement

MITSUBISHI
ELECTRIC
UF254
88C ABNORMAL
UF255
52C ABNORMAL
OUTPUT VOLTAGE
UF256
ABNORMAL
UF257
52C ABNORMAL
UPS CONTROL CIRCUIT
UF301
ERROR
UPS CONTROL CIRCUIT
UF302
ERROR
UPS CONTROL CIRCUIT
UF303
ERROR
UPS CONTROL CIRCUIT
UF304
ERROR
UPS CONTROL CIRCUIT
UF305
ERROR
UPS CONTROL CIRCUIT
UF306
ERROR
INVERTER VOLTAGE
UF309
ABNORMAL
UF351
CONTROL FUSE BLOWN Battery circuit's fuse burnt
SUPPLY OF CONTROL
UF352
CIRCUIT ABNORMAL
UF355
UPS CONTROL CIRCUIT
(Note10)
ERROR
UPS CONTROL CIRCUIT
UF356
ERROR
"INVERTER START "
UF357
BUTTON ABNORMAL
"INVERTER STOP "
UF358
BUTTON ABNORMAL
"INVERTER SUPPLY"
UF359
BUTTON ABNORMAL
"BYPASS SUPPLY"
UF360
BUTTON ABNORMAL
UPS CONTROL CIRCUIT
UF362
ERROR
UF401
52S ABNORMAL
UF402
52S ABNORMAL
UF451
52S ABNORMAL
AC INPUT VOLTAGE OUT
UA801
OF RANGE
AC INPUT FREQUENCY
UA802
OUT OF RANGE
AC INPUT PHASE
UA803
ROTATION ERROR
UA804
BATTERY ABNORMAL
(Note10)
UA805
AMBIENT TEMPERATURE
(Note10)
ABNORMAL
INVERTER OVERLOAD >
UA806
100%
INVERTER OVERLOAD >
UA807
110%
INVERTER OVERLOAD >
UA808
125%
INVERTER OVERLOAD >
UA809
150%
UA810
OVERLOAD
BYPASS VOLTAGE OUT
UA811
OF RANGE
9700 SERIES UPS
OWNERS / TECHNICAL MANUAL
Fan power source abnormality during operation
52C turned OFF during inverter power supply
Inverter output voltage fell out of +/- 5%
52C not turned OFF when manual transfer
Control microcomputer abnormality
Control microcomputer abnormality
Control microcomputer abnormality
Control microcomputer abnormality
Control circuit abnormality
Control power source circuit abnormality
Inverter output voltage abnormality before
inverter power supply
Control circuit abnormality
Control circuit abnormality
Control circuit abnormality
"INVERTER START" button is abnormal (Local)
"INVERTER STOP" button is abnormal (Local)
"INVERTER SUPPLY" button is abnormal
"BYPASS SUPPLY" button is abnormal
52S control circuit abnormality (Note 8)
52S not turned ON, or 52S turned ON without
any command
52S not turned OFF, or 52S turned OFF without
any command
52S not turned ON, or 52S turned ON without
any command when manual transfer
AC input voltage fell out of +/- 18% range
Ac input frequency fell out of converter
synchronization follow-up range
Phase rotation is inverted when input voltage is
normal
Battery abnormal (External input)
Temp. abnormality in room where installed
Overload exceeded 105% (Note 9)
Overload exceeded 110% (Note 9)
Overload exceeded 125% (Note 9)
Overload exceeded 150% (Note 9)
Momentary over-current during Inverter power.
Bypass voltage fell out of +/- 15% range at
manual transfer
MITSUBISHI ELECTRIC 9700 SERIES UPS
Page Number:
1
[1]
Minor
1
[1]
Minor
1
[1]
Minor
1
[1]
Minor
1
[2]
Major
1
[2]
Major
1
[2]
Major
1
[2]
Major
1
[2]
Major
1
[2]
Major
1
[2]
Major
1
[1]
Minor
1
[1]
Minor
1
[1]
Minor
1
[1]
Minor
1
[1]
Minor
1
[1]
Minor
1
[1]
Minor
1
[1]
Minor
1
[1]
Minor
1
[2]
Major
1
[2]
Major
1
[1]
Minor
3
[1]
Note 5
3
[1]
Note 5
3
[1]
Note 5
1
[1]
Note 5
11
[1]
4
[1]
Over
4
[1]
Over
4
[1]
Over
4
[1]
Over
4
[1]
Over
5
[1]
Note 5
6-3
Flicker
197
Flicker
128
Flicker
109
Flicker
98
Lit up
19
Lit up
28
Lit up
29
Lit up
31
Lit up
21
Lit up
16
Lit up
83
Flicker
115
Flicker
111
Flicker
130
Flicker
123
Flicker
124
Flicker
125
Flicker
126
Flicker
127
Flicker
195
Lit up
84
Lit up
85
Flicker
99
239
161
236
238
237
Flicker
216
Flicker
217
Flicker
218
Flicker
219
Flicker
220
240