Horizon Fireplaces 700 Low Line 700 Mk2 Pebble Installation Instructions Manual

Natural draft electronic ignition gas fireplaces

Advertisement

Quick Links

Installation Instructions
Horizon Natural Draft Electronic Ignition
Gas Fireplaces

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 700 Low Line 700 Mk2 Pebble and is the answer not in the manual?

Questions and answers

Summary of Contents for Horizon Fireplaces 700 Low Line 700 Mk2 Pebble

  • Page 1 Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces...
  • Page 2: Location Requirements

    Installation Instructions Horizon Natural Draft Electronic Ignition 3 Sided Gas Fireplaces Natural Draft Electronic Location Requirements Ignition approved for the Horizon natural draft electronic ignition fireplaces are designed to be installed as a complete fireplace system. following models: The firebox incorporates a gas burner with electronic ignition and spiggot for attaching a flue.
  • Page 3: Before Installation

    Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Before Installation Installation The Natural Draft Electronic Ignition (N.D.E.I.) flue 1. The N.D.E.I. system is supplied with all required system shall be installed by authorized personnel electrical fittings. Work needs to be undertaken by a in accordance with the manufacturer’s installation licensed electrician if extending wiring.
  • Page 4 Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces DOUBLE SIDED 700 Low Line 1000 850 Low Line 1095 1100 Low Line 1100 1358 1500 Low Line 1500 1746 1000 2000 Low Line 2000 2246 1000 * OPENING DIMENSIONS HEIGHT OF FIREBOX UNIT USING HEAT ZONE KIT.
  • Page 5 Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Measurements and Specification of N.D.E.I CANTILEVER Cantilever 700 1190 1266 Cantilever 1100 1424 1500 AGA Approved Cowl to suit flue sizes...
  • Page 6: Framing Dimensions

    Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Framing Dimensions DOUBLE SIDED 700 Low Line 1056 1050 850 Low Line 1145 1145 1100 Low Line 1408 1145 1500 Low Line 1796 1280 2000 Low Line 2293 1280 * including 10mm plasterboard INTERNAL FRAME HEIGHT WHEN USING HEAT ZONE KIT.
  • Page 7 Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Section SINGLE SIDED SECTION CANTILEVER SECTION Elevation SINGLE SIDED ELEVATION CANTILEVER ELEVATION...
  • Page 8: Gas Installation

    Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Gas Installation Laying the fire - Coal & Pebble 1. Check unit is suitable for intended gas supply. • Evenly spread a bag of Vermiculite into the burner 2. Note position on gas appliance on drawing specification tray.
  • Page 9 Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Laying the fire - Coal & Pebble MARK 2 COALS 700/800 - 600 x 155 MARK 2 PEBBLES 700/800 - 600 x 155 MARK 2 COALS 1000 - 992 x 155 MARK 2 PEBBLES 1000 - 922 x 135 MARK 2 COALS 1400 - 1400 x 64 MARK 2 PEBBLES 1400 - 1400 x 64...
  • Page 10 Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Laying the fire - 850 Ceramic Log POSITIONING OF ALL LOGS • It is important to follow the log recommended positioning. • Log NO. 6, 10, 9 and 4 must be pinned to rear log with pins provided.
  • Page 11 Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Laying the fire - 850 Ceramic Log 4. LOCATE LOG NO. 4: 6. LOCATE LOG NO. 9: Place it on the left side of the rear log. Charred end facing This log is placed on the rear log in the centre of the inwards.
  • Page 12 Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Laying the fire - 700 Ceramic Log POSITIONING OF ALL LOGS • It is important to follow the log recommended positioning. • Not doing so can adversely effect the operation of 2.
  • Page 13 Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Laying the fire - 700 Ceramic Log 4. LOCATE LOG NO. 4. 6. LOCATE LOG NO. 7. This log is placed with the thinner edge on the smaller The charred effect of the log is positioned on the smaller coal.
  • Page 14: Commissioning Procedure

    Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Commissioning Procedure 2. Initially the Kemlan coal fire may burn with a slightly blue flame. After approximately 20 minutes the fire will settle down and burn with a yellow flame. Installed correctly the burner should not emit any fumes 3.
  • Page 15 Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces...
  • Page 16 Wiring Diagram Head Office 13 French Avenue, Brendale Qld 4500 PH: (07) 3490 5500 FAX: (07) 3490 5520 www.kemlan.com For further service information contact Kemlan Australia Head Office: 13 French Avenue, Brendale Qld 4500 PH: (07) 3490 5500 FAX: (07) 3490 5520 www.kemlan.com...
  • Page 17 Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Service Instructions for Direct Ignition and Power Flue Horizon fireplaces POWER FLUE SERVICE INSTRUCTIONS PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION PILOT WILL NOT 1)NO GAS • CHECK FOR GAS SUPPLY AND TURN ON...
  • Page 18 Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Service Instructions for Direct Ignition and Power Flue Horizon fireplaces DIRECT IGNITION PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION PILOT WILL NOT LIGHT 1)NO GAS • CHECK FOR GAS SUPPLY AND TURN ON...
  • Page 19 Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Trouble shooting guide for Techrite ignition pack Warning: This is a 240VAC module. All connections to the module are 240V (except ignition cable and flame sense). Ensure power is switched off before checking any connection or replacing any components. There is a red LED (light) and a green LED (light) on the blue ignition box.
  • Page 20 Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Notes: The ignition unit is polarity sensitive. If the active and neutral cables are not wired correctly, the unit will not sense a flame, the green LED will not come on. The heater will light but will turn off almost immediately as a result. If the heater lights but the igniter keeps sparking then the unit shuts down after 3 to 5 seconds, incorrect polarity is a likely cause.
  • Page 21 Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces TAIS Flash Codes LED Flash Code Descriptions...