Wrong Card; Clean The User Card With A Sanitizing Towel; Dry And Re-Insert The Cleaned User Card; Replace Foamer Head - Melita Cafina c5-12C FF User Manual

Table of Contents

Advertisement

Wrong Card

EN

Clean the User card with a sanitizing towel

Dry and re-insert the cleaned User card

Replace Foamer Head

Check for proper connection of hose
 ttings to the foamer head
● Verify that the cover plate is
seated correctly
● Check that cover plate screws
are fully tightened
Note: Foamer cover plate has a safety switch in-
stalled in the machine. If the limit switch screw does
not make contact with the safety switch,
38
the message will not clear.
Basic Troubleshooting
User Card Still Does Not Work
● Try a different User or Manager card
● If a different card works, the fi rst User
card is bad
● A card from a different store may be
used
Call for a service technician if you are
unable to start or clean the machine
Basic Troubleshooting
Adjusting the foamer cover plate
limit switch screw
● Loosen retaining nut. Back off until it
touches the bottom of the screw head
● Tighten screw until it is fully seated
(should look like picture above)
● Loosen limit switch screw 2 full
revolutions and tighten nut
Note: Do not allow the limit switch screw
to turn while tightening the nut