11.4 Scan Direction

Feature
ScanDirectionMode
ExternalLine

11.5 GenICam Trigger

Feature Name
ExposureMode
TriggerSelector
TriggerSelector =
ExposureActive
TriggerMode
TriggerSource
TriggerActivation
TriggerDelayAbs
56
UM ELIIXA+ 16k CXP – Indice E - 06/13
CXP @
Size
in
bytes
0x0820C
4
0: Set scan direction to "forward"
1: Set scan direction to "reverse"
2: Set scan direction to "Externally controlled
direction via CC3 Camera Link (CC3=0 forward, CC3=1
reverse)"
0x08570
4
0: Line0
1: Line1
CXP @
Size
Bit field Description
bytes
0x08414
4
[31-30]
Not a register
0x08420
4
[31]
[30-26] Specifies the source for the trigger :
[25-23] Specifies the activation mode of the trigger :
[20-16]
Description
Operation mode for the exposure control:
0: Off
1: Timed
2: TriggerWidth
3: TriggerControlled
Select the trigger to control { ExposureStart,
ExposureEnd, ExposureActive}
Specifies the operation mode of the trigger for the
acquisition :
0: Off
1: On
0:Software
1: Line0
2: Line1
3: Line2
4: TimerStart1
5: TimerStart2
6: TimerEnd1
7: TimerEnd2
8: CounterStart1
9: CounterStart2
10: CounterEnd1
11: CounterEnd2
17: Line0 OR line1
18: Line0 AND Line1
19: RescalerLine
0: RisingEdge
1: FallingEdge
2: AnyEdge,
3: LevelHigh
4: LevelLow
Specifies the absolute delay in s to apply after the
trigger reception before effectively activating it
(0,31/30MHz,step 1/30MHz s)
ELIIXA+® 16k CXP
By default
0
0
By default
Timed
ExposureStart
Off
Software
RisingEdge
e2v semiconductors SAS 2013