  • Page 2: Table Of Contents

    Command Processing ..............................18 6.2.3 GenICam ready ................................18 Camera Commands ..........................19 6.3.1 Information ................................19 6.3.2 Image Format ................................22 6.3.3 Acquisition Control ..............................28 6.3.4 Gain and Offset ................................ 30 e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 3 APPENDIX D: Lens Mounts ..............51 10.1 F-Mount..............................51 10.2 T2 & M42x1 Mounts ..........................52 APPENDIX E: TROUBLESHOOTING............53 11.1 Camera..............................53 11.2 CommCam Connection........................... 53 APPENDIX F: Revision History ............. 54 e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 4: Camera Overview

    (in 2S or 4S mode and MultiGain at 1/2) electrons Response non linearity PRNU HF Max Dynamic range (1S / 2S / 4S mode) 67,6 / 70,7 / 68,7 e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 5: Description

    CE, FCC and RoHS compliant Description e2v’s next generation of line scan cameras are setting new, high standards for line rate and image quality. Thanks to e2v’s recently developed multi-line CMOS technology, the camera provides an unmatched 100,000 lines/s and combines high response with an extremely low noise level; this delivers high signal to noise ratio even when short integration times are required or when illumination is limited.
  • Page 6 Maximum data rate Stabilized temperature 30/40/55 °C (Room/Front Face/Internal) SNR Calculated at 75% Vsat with minimum Gain. In mode 2S/4S, only with the use of the Multi-Line Gain e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 7: Image Sensor

    ELIIXA+® 8k/4k CL Image Sensor The Eliixa+ 8k sensor is composed of two pairs of sensitive lines. Each pair of lines use ADC Column the same Analog to Digital Column converter Memory Node (ADC Column). An appropriate (embedded) Time delay in the exposure between each line...
  • Page 8: Response & Qe Curves

    ELIIXA+® 8k/4k CL 2.4 Response & QE curves 2.4.1 Quantum Efficiency Quantum Efficiency (%) 2.4.2 Spectral Response Response in 8k Pixels 5µm LSB12bits/(nJ/cm2)) e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 9 Response in 4k Pixels 10µm LSB12bits/(nJ/cm 2)) 1200 1100 1000 Response in 2k Pixels 20µm LSB12bits/(nJ/cm2)) 2400 2300 2200 2100 2000 1900 1800 1700 1600 1500 1400 1300 1200 1100 1000 e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 10: Camera Hardware Interface

    ELIIXA+® 8k/4k CL CAMERA HARDWARE INTERFACE Mechanical Drawings The Step file is available on the web : www.e2v.com/cameras e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 11: Input/Output Connectors And Led

    50 m 3.2 Input/output Connectors and LED USB Connector For Firmware Power Connector : upgrade 12-24V DC Multi-Colored LED for Status and diagnostic CameraLink Connector CL2 CameraLink Connector CL1 e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 12: Power Connector

    7.056 Power Time : Max 40s (Green Light) 10Taps 8bits 7.044 7.056 Medium 8bits 7.068 7.056 7.068 7.08 Medium 12bits Inrush Current Peak Current Establishment time and level e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 13: Status Led Behaviour

    (80/75/70/65/60MHz) Version BA1 (only) Full : 8 Channels 8bits 8 x 85MHz 8 x 1024 (80/75/70/65/60MHz) Deca : 10 Channels 8bits 10 x 85MHz 10 x 819 (80/75/70/65/60MHz) e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 14: Standard Conformity

    • A Camera Link data transfer cable ref. MVC-1-1-5-2M from CEI (Component Express, Inc.) e2v recommends using the same configuration to ensure the compliance with the following standards. CE Conformity The ELIIXA+ cameras comply with the requirements of the EMC (European) directive 2004/108/CE (EN50081-2, EN 61000-6-2).
  • Page 15 ELIIXA+® 8k/4k CL e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 16: Getting Started

    : This ensure you to have an up-to- date version. www.e2v.com/cameras Main Camera page : On the appropriate Camera Page (ELIIXA+ 8k/4k) you’ll find a download link first version of CommCam compliant is indicated in the last Chapter CommCam download requires a login/password : Login :...
  • Page 17: Camera Software Interface

    Beginner, Expert or Guru. Then you can make life easy for simple users. Minimum version of CommCam is 2.1.4 in order to recognize the ELIIXA+ 8k/4k Camera (both versions) e2v semiconductors SAS 2013...
  • Page 18: Serial Protocol And Command Format

    ELIIXA+ will have its correspondence with the Standard Feature Naming Convention of the GenIcam Standard. This correspondence is given in parenthesis for each feature/command as the following example : • DeviceVendorName Vendor name ( ) : “e2v” e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 19: Camera Commands

    • DeviceVendorName Vendor name ( ) : “e2v” Read function : “r vdnm”; Returned by the camera : “e2v”, string of 32 bytes (including “/0”) Can not be written • DeviceModelName Model Name ( : Internal name for GenICam : Read function : “r mdnm”;...
  • Page 20 Once the Standby mode turned off, the Camera recovers in less than 1ms to send Standby On images again from the sensor. Time (mn) e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 21 Bits 11 : Scrolling Direction : 0 = Forward, 1 = Reverse. Updated only by external CC3 (CameraLink) Bits, 12, 13, 14, 15 : Reserved StatusErrorHardware Bit 16 : ( ) : True if hardware error detected Bits 17 to 31 : Reserved e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 22: Image Format

    Medium 4 Channels 12bits 4 x 12 bits Full 8 Channels 8bits 8 x 8 bits (BA1 Version Only) Full+ 10 Channels 8bits 10 x 8 bits (BA1 Version Only) e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 23 10x409 pixels in Binning Mode 1SB or 2SB, 10x204 pixels in Binning mode 4SB. Ch 1 Ch 2 Ch 3 Ch 4 Ch 5 Ch 6 Ch 7 Ch 8 Ch 9 Ch 10 e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 24 Pixel Line D FPGA : (AB )+ (BC) This mode works in “Time delay Memory Node exposure” for the summation of each double line in the sensor. e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 25 D, normally, the variation of the Exposure time should not be possible in this sensor mode. Thanks to an e2v licensed solution, two of the Exposure controlled mode (Ext Trig with internal or External exposure control) are still available in 4S sensor TDE mode.
  • Page 26 Return by the Camera : 0 or 1 (enabled/disabled) Write function : “w revr <value>”; “0” : Disabled. “1” : Enables the reverse reading out (see below for “normal” direction) e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 27 In these case, the Trigger signification is : “0” : Forward. “1” : Reverse This positioning takes also in account that the mode “Reverse X” is “Off” (Normal readout direction) e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 28: Acquisition Control

    Write function : “w sync” <value> The Timing diagrams associated to each Synchronization mode and the Timing values associated are detailed in the APPENDIX B of this document. e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 29 The Tables of the minimum Line Period (Max Line Rate) versus the Data rate and the output mode chosen are given in Appendix C (Chap. 9.2) of this document. e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 30: Gain And Offset

    Returned by the camera : Integer corresponding to one of the 3 different step values : • 0 : x1 (0dB) • 1 : x2 (6dB) • 2 : x4 (12dB) Write function : “w pamp” <int> ; e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 31 ” returns Gain value Tap1. Write function : “w fgae <val>” with <val> : 0 or 1 0 : Disables the Tap Balance Gains 1 : Enables the Tap Balance Gains e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 32: Flat Field Correction

    When the FFC result is saved in memory, the adjust gain and target are saved in the same time in order to associate this gain value with the FFC result. e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 33 : You can perform one FFC per condition of Gain/setting of the Camera ( 4 Max) and recall one of the four global settings (Camera Configuration + FFC + Line Balance) when required. e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 34: Activation And Auto-Adjust

    The Maximum correction is x2 the highest value of the line. The reasonable value for the User Target is not more than around 20% of the max value of the line. e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 35: Automatic Calibration

    The Calculation result will be proposed anyway as it’s just a warning message. The Status Register is the changed and displayed in CommCam “Status” section : Register status is detailed chap §6.3.3. e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 36: Manual Flat Field Correction

    Write function :” w ffcg <addr><val> : Write 128 consecutive PRNU user coefficients starting from the <addr> address. <val> is the concatenation of individual PRNU values, without space between the values (one unsigned short per coefficient). e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 37: Ffc User Bank Management

    Reset a User bank : User1 Ram Memory - Reset the RAM Load User2 (FPN/PRNU individually) User3 - Save in the bank to User4 reset Reset FPN Reset PRNU e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 38: Look Up Table

    Upload / Download the LUT coefficients In CommCam, the User can access to a specific interface by clicking on “click for extended control” in the LUT section : e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 39 Upload/load from/to a Txt file User Save User1 Ram Memory Load User2 User3 User4 At the power up : - Last User Bank used is loaded in RAM e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 40: Statistics And Line Profile

    Returned by the camera : value between 1 and 16384 Write function : “w prow <val>” : Set the ROI width in pixels. <val> is between 1 and 16384 e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 41: Privilege Level

    Write function : “w lock <val>” : <val> is as follow 2 : Lock the Camera in Integrator or “privilege User” <computed value> : Unlock the Camera back in Integrator mode e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 42: Save & Restore Settings

    “Integrator” Bank (5) can be locked by switching the Camera in “User” mode (cf : Privilege feature). Then it can’t be saved any more without switching back the Camera in “Integrator” Mode. e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 43: Appendix A: Test Patterns

    7.2.1 In 8 bits (Full) format – No Binning (8192 pixels) An increment of 1 LSB is made every 8 pixels When it reaches 255, turns back to 0 and starts again e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 44: In 12 Bits (Medium) Format - No Binning (8192 Pixels)

    7.2.2 In 12 bits (Medium) format – No Binning (8192 pixels) An increment of 1 LSB is made for each pixel. When it reaches 4095, turns back to 0 and starts again e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 45: In 8/12 Bits Full/Medium Format With Binning (4096 Pixels)

    Pixel 31 : 33 Pixel 32 : 34 … Pixel 511 : 63 Pixel 512 : 96 Pixel 513 : 96 … Pixel 2047 : 255 Pixel 2048 : 32 … e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 46: Appendix B: Timing Diagrams

    12 bits : 24 s This conversion is done in masked time, eventually during the next exposure period. : Delay between the Start exposure required and the real start of the exposure. e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 47: Synchronisation Modes With Maximum Exposure Time

    The Real exposure time (Tint ) is finally equal to the Line Period ( ) even if it’s delayed real from ( ) from the rising edge of the incoming Line Trigger. e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 48: Timing Values

    ELIIXA+® 8k/4k CL 8.3 Timing Values Label Unit Tper Tint real 20 s 0,120 17 s 2,5 s 1,5 s 15 s Tint prog e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 49: Appendix C: Cameralink Data Cables

    Here is a following example of cable and the cable length limitation in accordance with the standard : DataRate Skew Cable Length 40Mhz 390ps 7,8m 66MHz 290ps 5,8m 70MHz 270ps 5,4m 80MHz 218ps 4,36m 85MHz 190ps 3,8m e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 50: Choosing The Data Rate

    1S, 2S, 4S (8K 5 m) 14.5/14.5 69.2/69.2 28.9/28.9 34.6/34.6 57.8 17.3 71.9 13.9 1SB, 2SB (4K 10 m) 28.9/28.9 34.6/34.6 57.8/40 17.3/25 10.0 (2K 20 m) 57.8/40 17.3/25 100/40 10.0/25.0 10.0 e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 51: Appendix D: Lens Mounts

    ELIIXA+® 8k/4k CL 10 APPENDIX D: Lens Mounts 10.1 F-Mount F Mount : Kit10 (Part number EV71KFPAVIVA-ABA) e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 52: T2 & M42X1 Mounts

    ELIIXA+® 8k/4k CL 10.2 T2 & M42x1 Mounts M42x0,75 (T2 Mount) : Kit30 (Part number AT71KFPAVIVA-AKA) M42x1 Mount : Kit40 (Part number AT71KFPAVIVA-ADA) e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 53: Appendix E: Troubleshooting

    : for Trigger or Check power supply Trigger too fast And its characteristics Contact Hotline 11.2 CommCam Connection Refer to CommCam software Help for the connection issues. e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 54: Appendix F: Revision History

    Comments / Details Firmware version CommCam Manual compliant Revision Version First release (Base Mode and Quarter Balance not available) Rev A Version BA0 1.0.0B 2.1.4 Version BA1 1.0.1A e2v semiconductors SAS 2013 UM ELIIXA+ 8k/4k CL – REVA – 01/13...
  • Page 55 Whilst e2v has taken care to ensure the accuracy of the information contained herein it accepts no responsibility for the consequences of any use thereof and also reserves the right to change the specification of goods without notice. e2v accepts no liability beyond that set out in its standard conditions of sale in respect of infringement of third party patents arising from the use of tubes or other devices in accordance with information contained herein.

This manual is also suitable for:

Eliixa+ 4k

Table of Contents