4.3. Local Dimming Function Check
(1) Turn on TV.
(2) At the Local Dimming mode, module Edge Backlight
moving right to left Back light of IOP module moving.
(3) Confirm the Local Dimming mode.
(4) Press "exit" Key.
4.4. Magic Motion Remote control test
- Equipment : RF Remote control for test, IR-KEY-Code
Remote control for test
- You must confirm the battery power of RF-Remote control
before test(recommend that change the battery per every lot)
- Sequence (test)
1) If you select the 'start key(OK)' on the Adjustment remote
control, you can pairing with the TV SET.
2) You can check the cursor on the TV Screen, when select
the "OK" key on the Adjustment remote control.
3) You must remove the pairing with the TV Set by select
'Mute + OK Key' on the Adjustment remote control.
4.5. 3D function test
(Pattern Generator MSHG-600, MSPG-6100[Support HDMI1.4])
* HDMI mode NO. 872 , pattern No.83
(1) Please input 3D test pattern like below.
(2) When 3D OSD appear automatically, then select green key.
(3) Don't wear a 3D Glasses, Check the picture like below.
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
4.6. Option selection per country
4.6.1. Overview
- Option selection is only done for models in AJ/JA/IL
4.6.2.Method
(1) Press "ADJ" key on the Adjustment remote control, then
select Country Group Menu.
(2) Depending on destination, select Country Group Code or
Country Group then on the lower Country option, select
US, CA, MX. Selection is done using +, - or ►◄ KEY.
4.7. HDMI ARC Function Inspection
(1) Test equipment
- Optic Receiver Speaker
- MSHG-600 (SW: 1220 ↑)
- HDMI Cable (for 1.4 version)
(2) Test method
1) Insert the HDMI Cable to the HDMI ARC port from the
master equipment. (HDMI2)
2) Check the sound from the TV Set.
3) Check the Sound from the Speaker or using AV & Optic
TEST program (It's connected to MSHG-600)
4.8. Tool Option selection
- Method : Press "ADJ" key on the Adjustment remote control,
then select Tool option.
Model
EU/CIS
Tool 1
65UG87_V-Z_
EU
34537
65UG87_9-Z_
EU
34537
65UG87_V-Z_
CIS
34537
4.9. Ship-out mode check (In-stop)
- After final inspection, press In-Stop key of the Adjustment
remote control and check that the unit goes to Stand-by
mode.
- 23 -
Tool 2
Tool 3
Tool 4
Tool 5
Tool 6
4628
58041
64601
59558
2379
4628
58041
64601
59558
2379
4632
58009
64601
59558
2379
LGE Internal Use Only
Tool 7
Tool 9
37007
3
37519
3
37519
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

65ug8709-za65ug870v65ug870v-za55uf770t55uf770v55uf770y

Table of Contents