To ensure that you get the best results from your new extractor, we strongly suggest that you read this instruction manual thoroughly before use..If treated with care, your Caple extractor should give you years of trouble-free use To register ownership, please ensure you complete and return the guarantee card supplied with the appliance.
Page 4
A damage supply cord must be replaced by qualified service personnel only. Please contact the Caple service department. If the room where the hood is to be used contains a fuel burning appliance such as a central heating boiler then its flue must be of the sealed or balanced flue type.
Installation Prepare for the installation: a. If you have an outlet to the outside, your cooker hood can be connected as below picture by means of an extraction duct with an interior per the diameter of 120mm) b. Before installation, turn the unit off and unplug it from the outlet. c.
Page 6
Installation – ducted Attent Attention! Observe the warning Attent Attent ion! Observe the warning ion! Observe the warning concerning the operation of the appliance ion! Observe the warning concerning the operation of the appliance concerning the operation of the appliance concerning the operation of the appliance when air is discharged from the room.
Page 7
Note: 1.The ducting tube is not supplied with the extractor. 2.Take off the protective film before installation. 3.There are 2 methods for ducting , including ' rear ventilation' and ' vertical ventilation'. Please pay attention to the ventilation method when installing. Vertical ventilation: See Pic A, please use a tool take out the round cover before using, the air can now be vented from top.
Air e e e e xtraction xtraction setting setting xtraction xtraction setting setting D D D D ucted installation ucted installation: Turn the adjuster to the ducted position, install the ucted installation ucted installation outlet, turn on the cooker hood. The air will be extracted to the outside outlet.
Installation – recirculation mode If you do not have an outlet to the outside, the exhaust pipe is not required (as shown in the section “Installation - ducted”). Operation 0 Off button 0 Off button 0 Off button 0 Off button It’s used for turning off the fan.
Care and maintenance IMPORTANT: Before cleaning or maintenance please switch off the electricity supply and remove the plug from the wall. Regular Regular Regular Regular c c c c leaning leaning leaning leaning Use a soft cloth moistened with lukewarm mildly soapy water or household cleaning detergent.
Page 11
Replacing the bulb Replacing the bulb Replacing the bulb Replacing the bulb 1.Switch the unit off and unplug the appliance. 2.Remove the lamp cover by unscrewing the 2 screws. 3.Unscrew the incandescent bulb 4.Replace with the same type and rated bulb/lamp: E14 Incandescent Bulb: (220V E14 Max 40W).
‘Care and maintenance’ section. The filter requires cleaning performance is Replace the charcoal filter (if in not good recirculation mode) If the above table has not solved the problem please contact Caple Service by phone on 0844 800 3830 or by email service@caple.co.uk...
Guarantee Caple undertake that if within twelve months of the date of the purchase this appliance or any part thereof that is proved to be defective by reason only of faulty workmanship or materials, we will at our option repair or replace the same free of...
CE Declarations of Conformity This appliance has been manufactured to the strictest standards and complies with all applicable legislation, Low Voltage Directive (LVD) and Electromagnetic Compatibility Directive (EMC). Caple Fourth Way Avonmouth BS11 8DW www.caple.co.uk...
Need help?
Do you have a question about the FSCHSS7 and is the answer not in the manual?
Questions and answers