Strobe Connection; Connection To Strobe - Ikelite DS51 Instructions Manual

Digital strobe
Hide thumbs Also See for DS51:
Table of Contents

Advertisement

STR OBE CON N EC TI ON
The female Ikelite bulkhead connector permits Ikelite sync cords to be connected to the
strobe. The sync cord relays a signal from the camera to the strobe that tells the DS51 when
to flash.
The removable waterproof bulkhead cap seals the bulkhead connector when a cord is
connected to the DS51. The strobe's bulkhead connector must be sealed to remain
waterproof (page 7).
Caution:
Do not leave the sync cord connected to the camera housing or strobe
-
for prolonged periods as electrolysis could occur and make removal of the
equipment impossible.
-
Do not disconnect the sync cord from the camera housing or strobe when
underwater, or when wet. These items are not waterproof when disconnected.

CONNECTION TO STROBE

To connect a sync cord to the DS51 Strobe, follow these instructions:
1.
Turn the strobe to OFF and make sure all components are dry. Clean and
lightly lubricate the stem o-ring and the bulkhead connector threads.
Check the o-ring for nicks or cuts.
2.
Note the positioning of the receptacles and pins on the end of the cord. Properly
align the end of the cord and insert it into the strobe bulkhead connector.
When using the 4103.51 cord, which connects an Ikelite housing to an Ikelite
strobe, both cord ends are identical; either end can be connected to the
strobe.
3.
The connector threads are very fine; do not cross thread. If it is difficult
to turn the knurled retaining ring on the cord or sensor, you are cross-threading.
This can make removal of the strobe impossible.
Hand-tighten the knurled retaining ring on the cord. Push the end of
the cord further into the bulkhead connector and continue to tighten the knurled
retaining ring. Do not use a tool when tightening. It could damage the
cord or strobe.