Download Print this page

Little Giant 5-ASP-FS Instruction Manual page 2

Water wizard automatic sump pump

Advertisement

to normal "on" level and allow pump to remove water to the
normal "off" level (Figure 1).
7. Place the cover over the sump. This cover will prevent solid
debris from filling the pit, reduce odors, and guard against
accidental injury.
MAINTENANCE
The motor housing of the pump is completely sealed and requires
no service. Disassembly of the motor housing or alteration of the
power cord voids all warranty.
The motor is continuous duty type sealed in oil with an automatic
thermal overload protector device.
The pump can run against a restricted discharge (such as a
fountain) without damage to the pump.
1. If the pump becomes clogged, snap the screen off and clean
out the area.
2. If necessary, remove the six screws holding the volute base to
the motor housing and clean the volute.
3. If the impeller is removed, make sure that a spacing of
.050" with shaft pushed toward housing is maintained when
reassembling (Figure 2).
4. When reassembling, ensure that you install the seal ring
between the volute base and the motor housing.
PERFORMANCE DATA
Maximum pumping height = 26.3'
Maximum PSI = 11.4 PSIG
Discharge height
above pumping level
Gallons per minute
(water)
Note: Ratings based on 1" pipe with friction loss neglected.
Using 3/4" garden hose adaptor performance will be reduced
approximately 15%. This pump does not deliver enough pressure
to operate lawn sprinklers properly.
2
1'
3'
5'
10'
20.4
20
19
16
15'
20
13
8
TYPICAL INSTALLATION