Main CBA Top View
CAUTION !
Fixed voltage power supply circuit is used in this unit.
If Main Fuse (F601) is blown, check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
CAUTION
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,
REPLACE ONLY WITH THE SAME TYPE FUSE.
1-8-27
Sensor CBA Top View
WF3
WF5
BHB300F01011-A
TP001
TP003
CTL
V-OUT
BHB300F01011-B
1-8-28
BECAUSE A HOT CHASSIS GROUND IS PRESENT IN THE POWER
SUPPLY CIRCUIT , AN ISOLATION TRANSFORMER MUST BE USED.
ALSO , IN ORDER TO HAVE THE ABILITY TO INCREASE THE INPUT
SLOWLY , WHEN TROUBLESHOOTING THIS TYPE POWER SUPPLY
WF6
WF8
WF1
J219
CIRCUIT , A VARIABLE ISOLATION TRANSFORMER IS REQUIRED.
TP004
TP007
TP002
B-OUT
NOTE :
C-PB
A-OUT
RF-SW
(C-Trap Adjustment)
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
1-8-29
BT6300F01011-A