13. Focus Adjustment
Purpose: Set the optimum Focus.
Symptom of Misadjustment: If Focus Adjustment is
incorrect, blurred images are shown on the display.
Test point
Adj. Point
Screen
Focus Control
Tape
M. EQ.
---
Pattern Generator
Note: Focus VR (FBT) --- H.V./Power Supply CBA
FBT= Fly Back Transformer
1. Operate the unit more than 30 minutes.
2. Face the unit to the East and degauss the CRT
using a Degaussing Coil.
3. Input the monoscope pattern.
4. Adjust the Focus Control on the FBT to obtain clear
picture.
Mode
Input
---
Monoscope
Spec.
See below.
1-6-7
14. Head Switching Position Adjustment
Purpose: Determine the Head Switching Point during
Playback.
Symptom of Misadjustment: May cause Head
Switching Noise or Vertical Jitter in the picture.
Note: Unit reads Head Switching Position automati-
cally and displays it on the screen (Upper Left Corner).
1. Enter the Service Mode. (See page 1-6-1.)
Then press the number [5] button on the remote
control unit.
2. Playback the test tape (FL6A).
3. The Head Switching position will display on the
screen; if adjustment is necessary follow step 4.
6.5H(412.7µs) is preferable.
4. Press [P+/P-] buttons on the remote control unit if
necessary. The value will be changed in 0.5H steps
up or down. Adjustable range is up to 9.5H. If the
value is beyond adjustable range, the display will
change as:
Lower out of range: 0.0H
Upper out of range: -.-H
5. Turn the power off and on again.