Disassembly
13. Motor
1. Remove the cabinet. (Refer to section 2)
2. Remove the evaporator. (Refer to section 4)
3. Remove the orifice. (Refer to section 4)
4. Remove the blower. (Refer to section 4)
5. Remove the fan. (Refer to section 5)
6. Remove the control box cover and disconnect 5
or 4 wires of motor housing. (Refer to section 3)
7. Remove the 2 or 4 screws that fasten the motor
from the mount motor. (See Figure 28)
8. Remove the motor.
9. Re-install the components by referring to the
removal procedure, above.(See Figure 28)
Refrigerating Cycle
CAUTION: Discharge the refrigerant
system using a Freon
System. If there is no valve to attach
the recovery system, install one
(such as a WATCO A-1) before vent-
ing the Freon
place after servicing the system.
14. Condenser
1. Remove the cabinet. (Refer to section 2)
2. Remove the 4 screws which fasten the
brace.(Refer to section 4)
3. Remove the 5 screws which fasten the con-
denser and shroud.
4. After discharging the refrigerant completely,
unbraze the interconnecting tube at the con-
denser connections.
5. Remove the condenser.
6. Re-install the component by referring to notes.
(See Figure 29)
15. Evaporator
1. Remove the cabinet. (Refer to section 2)
2. Remove the 2 screws that fasten the evaporator.
3. Move the evaporator sideways carefully.
(Refer to section 4)
4. After discharging the refrigerant completely,
unbraze the interconnecting tube at the evaporator
connections.
5. Remove the evaporator.
6. Re-install the component by referring to notes.
(See Figure 30)