1.Set t heOn/Off switch ( A) t oOFF and unplug u nit.
2.Allow themotor tocool.
3.Plug thepower cordinto the correct branch c ircuit receptacle.
4.Set t heOn/Off switch t oONposition.
DUTY CYCLE (NOT SHOWN}
This air compressor
pump is capable of running continuously.
However, to prolong the lifeof your air compressor, it is recommended
that a 50% average duty cycle be maintained; that is, the air
compressor pump should not run more than 5 minutes in any 10
minute period.
iNSTALLATiON
Grounding
instructions
(Fig. 2)
AkWARNING: Risk of Electrical
Shock. In the event of a short
circuit,
grounding
reduces
the risk of shock by providing
an
escape wire for the electric current.
This air compressor
must
be properly
grounded.
The portable air compressor
is equipped with a cord having a
grounding wire with an appropriate grounding plug (J).
1. The cord set and plug (J)with this unit
FIG.2
contains a grounding
pin (L). This
plug MUST be used with a grounded
outlet (K).
IMPORTANT:
The outlet
being used
must
be installed
and grounded
in
accordance
with all local codes
and
ordinances.
2. Ensure the outlet being used has the same configuration as the
grounded plug. DO NOT USE AN ADAPTER.
3. Inspect the plug and cord before each use. Do not use if there are
signs of damage.
10
4. If these grounding instructions are not completely understood, or
if in doubt as to whether the compressor is properly grounded,
have the installation checked by a qualified electrician.
_DANGER:
Risk of Electrical
Shock. IMPROPER GROUNDING
CAN RESULT IN ELECTRICAL
SHOCK.
, Do not modify
the plug provided,
if # does not fit the
available
outlet, a correct
outlet
should
be installed
by a
qualified electrician.
• Repairs to the cord
set or plug
MUST be made
by a
qualified electrician.
Extension
Cords
If an extension cord must be used, be sure it is:
• a 3-wire extension cord that has a 3-blade grounding plug, and a
3-slot receptacle that will accept the plug on the product
• in good condition
,, no longer than 50' (15.2 m)
,, 14 gauge (AWG) or larger. [Wire size increases as gauge number
decreases. 12 AWG and 10 AWG may also be used. DO NOT
USE 16 OR 18 AWG.)]
NOTICE:
Risk of Property Damage.
The use of an undersized
extension cord will cause voltage to drop resulting in power loss to the
motor and overheating. Instead of using an extension cord, increase
the working reach of the air hose by attaching another length of hose
to its end. Attach additional lengths of hose as needed.
Voltage
and Circuit
Protection
Refer to the Voltage and Minimum Branch Circuit Requirements under
Pump/Motor
Specifications.
_ WARNING: Risk of Overheating. Certain air compressors can be
operated on a 15 amp circuit if the following conditions are met.
• Voltage supply to circuit must comply with the National Electrical
Code.