Kenmore 153.329266 Use & Care Manual page 14

Table of Contents

Advertisement

5.
6.
LIFT OUT TAB TO UNCLIP
TERMINAL COVER FROM
THERMOSTAT
TURN
OFF
POWER
BEFORE
SERVING
COVER
TO REMOVE
PULL
ARROW
AT TOP OF
FIGURE 16.
Remove the screws from terminal 2 of the element, and
move the looped end of the wire aside.
FIGURE 17.
The buss bar is labeled 5500 W. Place the buss bar over
terminals 2 and 3 with the 5500 W visible. Install the extra
screw provided into terminal 3.
IIIIIIIIIIIII
8.
Tighten
terminals
2 and 3 to ensure
proper electrical
connection.
Fire and Explosion
Hazard
" Failure to tighten screws can
cause a fire.
,, Failure to do this could result in
death, serious bodily injury, or
property damage.
Failure to tighten terminal screws can cause a fire which can
result in DEATH, SERIOUS BODILY INJURY, OR PROPERTY
DAMAGE.
9.
Replace terminal cover on thermostat making sure that the
locking tabs on the terminal cover are in place.
place
Fire and Explosion
Hazard
• Thermostat
must
be
flush
against the tank.
• Make sure terminal cover is in
and
the
insulation
replaced.
• Failure to do this could result in
death, serious bodily injury, or
property damage.
Make sure the thermostat is flush against the tank, the terminal
cover is in place, and the insulation
is replaced.
Failure to
do so can result in DEATH, SERIOUS BODILY INJURY, OR
PROPERTY DAMAGE.
10. Replace the insulation
so that it completely
covers the
thermostat and elements.
7.
FIGURE 18.
The wire removed from terminal 2 has a looped end. It must
remain looped and now be placed (as shown) on top of the
buss bar, over the opening of terminal 2, and secured using
the remaining screw.
FIGURE 19.
14
FIGURE 20.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

153.329564153.329364153.329464

Table of Contents