Problems solution

Defect
Boiler has a lower output as it was
a new one
Afterclosing the flue shutter the boiler
burns for a while and then smoke
In
combustion
pieces of unburnt logs.
Smoke escape over the closed door.
Flue shutter does not open.
After opening the upper door and
chimney shutter the boiler room is full
of smoke
Boiler does not seal
Failure of electronic regulation
chamber
arebigger
Cause/Remedy
- Clean up air inlet system
- Clean up blades of fan
- Use dry wood
- Insufficient quantity of primary air
- Clean up the primary air inlet
- Check the shutter opening behind the fan
- Nozzle opening Increased
- Change the nozzle
- Set the air inlet into a closed position and turn
3 turns back from the closed position.
- set up the door, check the tightness of the
door
- Change the sealing cord of the door
- Flue shutter is sticked with tar
- Increase the boiler temperature
- Use the dry wood
- Open flue shutter manually
- Low flue draught
- The flue diameter should be bigger than the
diameter of boiler flue connection. It is
recommended 200mm.
- Chimney heigth should be minimum 8m
- Assembly suction fan
- Increase the chimney heigth
- Contact service worker or dealer
- Contact service worker or dealer