4-4. Trigger Mode Selection

L10
L11
L12
P1
.
Always check and set a trigger mode.
If trigger mode is undefined for a weld-
ing process, select the desired mode.
Trigger mode can be set for Manual MIG,
Synergic MIG, Synergic Pulsed MIG, and
Synegic Double Pulsed MIG welding to
change when output power is present at
the weld connectors. In Manual MIG, Syn-
ergic MIG, Synergic Pulsed MIG, and Syn-
ergic Double Pulsed MIG welding, press-
ing P1 will change trigger mode, but D1 and
D2 will not change values.
Press P1 to select the desired trigger
mode:
L10 ON selects 2 times trigger function.

4-5. Setup Menu and Memory Menu Selection

L13
L14
P2
When trigger is pressed, welding starts.
When trigger is released, welding stops.
L11 ON selects 4 times trigger function.
When trigger is pressed, welding starts.
When trigger is released, welding contin-
ues.
When trigger is pressed and released a
second time, welding stops.
L12 ON selects 3 levels trigger function.
When trigger is pressed, welding starts
with level 1 parameters.
When trigger is released, welding contin-
ues with main parameters.
When trigger is pressed a second time,
welding continues at level 2 parameters.
When trigger is released the second time,
welding stops.
L12 trigger mode is useful for aluminum
and for a crater fill sequence.
In Manual MIG process, 2 times and 4
times trigger mode can be selected.
In Synergic MIG process, 2 times, 4 times
and 3 levels can be selected.
In Synergic Pulsed MIG process, 2 times,
4 times, and 3 levels can be selected.
In Synergic Double Pulsed MIG process, 2
times, 4 times, and 3 levels can be se-
lected.
L13 and L14 are generally OFF.
P2 selects the Setup Menu and the ad-
vance programming of MIG welding and to
memorize and manage personal welding
parameters in MIG welding.
Press P2 to select Setup Menu. L13 is ON.
Press P2 a second time to select Memory
Menu. L14 is ON.
Press P2 again to exit Setup and Memory
Menu. L13 and L14 are OFF.
In order to complete Setup and/or Memory
procedures you have to exit these menus.
L13 and L14 must be off.
.
In Setup Menu and Memory Menu you
cannot weld. This avoids setting er-
rors in the welding parameters and in
the memorized welding parameters.