FIGURE 12
TROUBLESHOOTING
Lights do not turn on
Make sure the wiring connection is correct.
Ensure that you are within detection range. Adjust
the PIR sensor angle if necessary.
Adjust the LUX control knob by turning it
counterclockwise.
Lights remain on
Make sure the wiring connection is correct.
Adjust the TIME control knob by turning it
counterclockwise.
Make sure that the unit is not in Manual Override mode.
Others
Check with your electrician who did the installation.
40°
80°
SPECIFICATIONS *
Power Requirement
Lighting Load
Standby power usage
LED
Color Temperature (K)
CRI
Lumen (lm)
Beam Adjustment Angle
L70 Life Span (hours)
Detection Angle
Detection Range
PIR Sensor Adjustment
Angles
Spotlight Heads
Adjustment Angles
Mounting Height
Time Adjustment
Lux Adjustment
Operation Mode
Warm Up Time
Working Temperature
Protection Class
IP Protection
*Specifications are subject to change without notice.
TITANTF10WLED-FA
Environmental Concerns:
Please DO NOT dispose of electrical appliances as
unsorted waste, use the recycling facilities provided by
your local authorities.
Please DO NOT dispose of packaging as unsorted waste,
use the recycling facilities provided by your local
authorities.
4
AC 220 - 240V / 50Hz
10W (5W x 2) LED
0.5W
Cree XBD x 4
5000K
>70
Up to 550lm (275lm x 2)
40° ~80°
Up to 30000 hr
Up to 180° at 2m Height
Up to 12m (39.4ft) at 2m
Height
Up to 45° Left
Up to 45° Right
Up to 35° Vertical
o
Up to 45
Left
Up to 45° Right
Up to 37.5° Vertical
Recommended 2m Brick
Wall Mount
5 seconds - 12 minutes
30 - 200 Lux
Auto/Manual override
About 60 seconds
-20°C - +40°C
Class II Double Insulated
IP44
2014/10