Watts Per Channel at - 8 Ω:
Watts Per Channel at - 4 Ω:
Watts Per Channel at - 2 Ω:
Watts Bridged (A and B) - 8 Ω:
Watts Bridged (A and B) - 4 Ω:
Average Supply Current, Full Load:
THD (20Hz - 20kHz, full power):
Damping Factor (ref. 8R, 100Hz):
Cooling Fan Arrangement:
(Temperature controlled dual speed fans)
Operating Environment:
The amplifier is designed for use in environments which protect it from rain, unusually
l
high air humidity and temperature.
When mounting inside, ensure that the amplifier is securely bolted into a rack using all
l
available fixing points where possible. Otherwise place on a surface where it cannot be
easily displaced, Potentially causing damage/injury. Ensure That the location will not
expose the amplifier to spillage of liquids/drinks, sprays/vapours or high humidity. Ensure
the amplifier is installed in a place which is not subject to abnormally high temperatures
and maintain sufficient ventilation to prevent overheating.
For temporary use outside, apply similar caution; however be extra sure to ensure
l
placement accounts for changing weather conditions and that extreme wind/rain/heat will
not find its way to equipment.
When taking any equipment from a cold environment (unheated storage, vehicles, etc),
l
into a warm one, allow the equipment time to acclimatise to the ambient temperature, as
condensation is likely to form in the amplifier, potentially causing it to malfunction if put
into service too soon.
Note: Our policy of continuous improvement may lead to the above specifications being

2.1 Technical Specifications

Number of Channels:
Supply Voltage:
Mains Connector:
Frequency Response:
Signal to Noise Ratio
(ref. Full power 1kHz):
THD (1kHz, full power):
Slew Rate:
Cooling Airflow Direction:
Dimensions (mm):
Additional Features:
exceeded prior to documentation being updated.
UK500
230V +/- 15% 230V +/- 15%
10A IEC
8–24,000 Hz
0.06%
<0.1%
50 V/µs
2x 40mm
Front to Back
482 X 44 X 210 482 X 44 X 210
Weight:
UK800
2
150
250
250
400
-
500
800
-
3A
10A IEC
8–24,000 Hz
96 dB
96 dB
0.06%
<0.1%
50 V/µs
>350
>400
2x 40mm
Front to Back
3.6 Kg
3.7 Kg
-
2
-
-
4A
-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uk 800