. l a m b a p l c . c o m Field Acoustics are distributed by: Lamba plc, Unit 1, Southfields Road, Dunstable, Bedfordshire, United Kingdom LU6 3EJ Telephone: (+44) (0)1582 690600 • Fax: (+44) (0)1582 690400 • Email: mail@lambaplc.com • Web: www.lambaplc.com If this product is ever no longer functional please take it to a recycling plant for environmentally friendly disposal.
Congratulations on the purchase of your new Page Field Acoustics power amplifier. Thank You Field Acoustics amplifiers are the result of many decades of experience in the design of 1. Features and Innovations exceptionally robust and reliable amplifiers. 2. Specifications...
1. Features and Innovations All our amplifiers have been designed to give the best possible performance for their intended application and are based on our own uncompromising, time proven MOSFET designs. These take advantage of components which will stand the test of time and give the best possible performance in a small, exceptionally light weight package.
2.1 Technical Specifications UK500 UK800 Number of Channels: Watts Per Channel at - 8 Ω: Watts Per Channel at - 4 Ω: Watts Per Channel at - 2 Ω: Watts Bridged (A and B) - 8 Ω: Watts Bridged (A and B) - 4 Ω: Supply Voltage: 230V +/- 15% 230V +/- 15% Average Supply Current, Full Load:...
3. Interface Elements, Front Panel. (1) Power Switch This switch controls the power supply to the amplifier. There is a short delay on power-up, this is to avoid switch-on "thump" which could damage the loudspeakers. (2) Gain Controls The level of each Channel is individually adjusted by these controls. Rotating these controls fully clockwise, results in no attenuation to the incoming audio signals.
3. Interface Elements, Rear Panel. (5) Cooling Fan Outlet Hot air exits here. M ake sure all rear (and front) ventilation paths are free from obstruction and air flows freely, otherwise the amplifier will trip into thermal protect mode prematurely and in some extreme circumstances damage may occur. (6) Output Connectors The Output sockets are Neutrik Speakons and accept a Neutrik NL4FC plug.
Page 8
(7) Input Signal Sockets These are combined female XLR and 1/4" jack sockets. They provide a number of connection possibilities, including the industry standard Balanced XLR system, which helps ensure interference and noise free connections between equipment. Ready-made, sensibly priced, quality interconnection leads suitable for use with the amplifier should be easy to source.
4. Recommended Usage: To ensure your speaker and amplifier system functions optimally, it is advised to read through everything covered in this manual. Safety precautions and appropriate usage recommendations for specific connections and features are noted in the previous section. 4.1 Matching Speakers to the amplifier: When matching loudspeakers appropriately to the available amplification, it is generally best to ensure that their power rating in watts rms (or aes) is more or less the same for the rated...
Page 10
4.2 Using Bridge Mode: Only use this mode of amplifier operation where the power available from one amplifier output channel alone, is not sufficient for the connected speaker system. This mode works by using two amplifier output stages together in series, using specialised internal amplifier circuitry.
5. Cables, Making your own. 5.1 Signal Level Leads. Standard Audio Connectors: R E A R S ID E
F R O N T (IN S ID E ) G rou n d
Ta b , X L R ,
M a l e : S h e ll G rou n d G rou n d...
5.2 Speaker Leads. Speakon Connectors, 4 Pin: R E A R S I D E
V I E W ( I N S I D E ) -‐ 1 1 -‐ 2 -‐ -‐ 2 Cable Maker Table: Cable Connections: Cable Type: + and -...
Page 13
The previous table is a rough guide for recommended cable gauges. It is important to use sufficiently heavy duty cables (try to use at least 2.5mm ) and plan the use and instillation of sound equipment such that the speaker cables in particular are kept short where possible (under 6m/20ft should provide enough flexibility to cover most applications).
- especially in bridge mode If any of these, or other symptoms persist, Please contact us with the details below for help, advice and service: Contact Details: Address: FIELD ACOUSTICS, Distributed by Lamba plc Unit 1 Southfields Road Dunstable...
Warranty work can only be performed at our authorised distributors or at Field Acoustics. We will remedy the defect and ship the product from the service centre or our own factory within a reasonable time after receipt of the defective product. All expenses in remedying the defect, including freight costs from ourselves to you (within mainland UK) will be borne by us.
Declaration of CE Conformity Issuers Name and Address: Andrew Hunt, Cordes House, Factory Road, Newport, Gwent, United Kingdom. NP20 5FA Products: UK500 / UK800 Equipment Type: Commercial Audio Power Amplifiers. Safety Standard: AMD1: 2005 and IEC Safety Requirements - Audio Video and Similar Electronic Apparatus. 60065: 2001 7th Ed.