York PC9B12N060UP11 Technical Manual page 8

Hide thumbs Also See for PC9B12N060UP11:
Table of Contents

Advertisement

246813-YTG-D-0108
HP 28C
Two Stage Heat Pump – Variable Speed Modulating Furnace (With Hot Heat Pump Operation)
THERMOSTAT
*PP32U70124
C
24 – Volt Common
Y
First Stage Compressor
R
24 – Volt Hot
(Heat XFMR)
G
Fan
E
Emergency Heat
RC
24 – Volt Hot
(Cool XFMR)
O/B
Reversing Valve
L
Malfunction Light
Y2
Second Stage Compressor
AUX
Auxiliary Heat
3
Thermostat Installer Setup
0170-System Type-
must be set to 12
3 Heat/2 Heat Pump
Thermostat Installer Setup
0190-Changeover Valve-
must be set to 0
O/B terminal
Energized in Cooling
Thermostat Installer Setup
0200-Backup Heat Source-
must be set to 1
Heat Pump Backup Heat
Source is Fossil Fuel
Thermostat Installer Setup
0210-External Fossil Fuel
Kit- must be set to 1
Heat Pump Control
is Controlling Heat Pump
Backup Heat
Thermostat Chart -
8
THERMOSTAT
*DN22H00124
*DP22U70124
C
24 – Volt Common
Y1
First Stage Compressor
R
24 – Volt Hot
G
Fan
W2
Second Stage Aux. Heat
O
Reversing Valve
Energized in Cool
L
Malfunction Light
Y2
Second Stage Compressor
E/W1
First Stage Aux. Heat
External Humidistat
(Optional)
Open on Humidity Rise
Step 1 of Thermostat
Installer/Configuration
Menu must be set to "HP2"
Selection of GAS/ELEC
switch on thermostat
not necessary
ID MODELS
PC9
FC9C
FL9C
VARIABLE SPEED
MODULATING
FURNACE
VARIABLE SPEED
2
MODULATING
FURNACE CONTROL
C
24 – Volt Common
Y1
Single Stage Compressor
R
24 – Volt Hot
G
Fan
W
Modulating Heat
Y/Y2
Second or Full
Stage Compressor
HUM
Dehumidification-
Open on Humidity Rise
Bonnet Sensor
Move HUMIDISTAT
jumper to "YES"
if humidistat is to be used.
Part Numbers:
2
SAP =
Legacy
171334 = 031-09153
OD MODELS
YZE
YZH
H*5
H*8
TWO STAGE
HEAT PUMP
YORKGUARD VI
CONTROL
C
24 – Volt Common
Y1
Single Stage Compressor
R
24 – Volt Hot
W1 OUT
First Stage Heat
W2 OUT
Second Stage Heat
Y2 OUT
Second Stage Compressor
O
Reversing Valve
Energized in Cool
X/L
Malfunction Light
Y2
Second Stage Compressor
W
Auxiliary Heat
BSG
Bonnet Sensor
(Optional)
BS
Bonnet Sensor
Change FFuel jumper
on the heat pump control
to "ON"
Change Hot Heat Pump
jumper on the heat pump
control to "ON"
Part Numbers:
SAP =
Legacy
126768 = 031-09137
18395 = 031-01996
340512 = 031-09178
Unitary Products Group