Miele DA 6480 Operating And Installation Instructions page 38

Downdraft ventilation system
Table of Contents

Advertisement

Electrical connection
Electrical connection if using an
external blower
If using the external blower, install a
connection cable between the
ventilation system and the external
blower.
Please follow the Operating and
Installation Instructions for the
DAG 1000.
^ Additional housing knock-outs should
be used for the external blower
housing.
^ Install a suitable UL listed cable
clamp or conduit fitting into the
knock-out.
38
^ Connect to the power supply as
described previously.
^ The external blower will be
connected to the additional control
cable.
^ Close the terminal box.
^ Turn the power supply back on.
Maximum load
with interior-mounted
DAG 500 vent motor . . . . . . . . . . 420 W
with exterior-mounted
DAG 1000 vent motor . . . . . . . . . 210 W
Voltage . . . . . . . . . . . . . . . . . . . . . 120 V
Frequency . . . . . . . . . . . . . . . . . . 60 Hz
Circuit Rating . . . . . . . . . . . . . . . . . 15 A