Installation instructions
Do not install the DA 8-2 directly
next to a gas hob.
This extractor is designed for installa-
tion between Combiset appliances.
It should always be installed between
two appliances, such as the grill and
deep fryer.
Prepare the countertop cut-out as il-
lustrated.
Dimension "B" will vary depending
on how many combisets are in-
stalled. The following chart gives
dimension "B" for a variety of 2 zone
(ie KM 88-2) and 4 zone (ie KM 93-2)
combinations.
14
2 zone Combiset
1 combiset
2 combisets
3 combisets
4 combisets
5 combisets
4 zone Combiset
1 combisets
2 combisets
3 combisets
Combination
One 2 zone
+ one 4 zone
Two 2 zone
+ one 4 zone
Three 2 zone
+ one 4 zone
One 2 zone
+ two 4 zone
Two 2 zone
+ two 4 zone
Extractor (e.g. DA 8-2)
For installation between two appliances:
- Dimension B increases by 90 mm.
For installation at the end of a combination:
- Dimension B increases by 98 mm.
Depth
Width
(in
(= Dimen-
mm)
sion B)
(in mm)
490
265
490
558
490
851
490
1144
490
1437
490
560
490
1143
490
1728
490
851
490
1143
490
1437
490
1436
490
1729