Gas fired hot water heating boiler

Advertisement

Quick Links

Do not use this boiler if any part has been under water. Immediately call a qualified service technician to
inspect the boiler and to replace any part of the control system and any gas control which has been under
water.
Should overheating occur or the gas supply fail to shut off, do not turn off or disconnect the electrical supply to
the pump. Instead, shut off the gas supply at a location external to the appliance.
INFORMATION
GAS FIRED HOT WATER HEATING BOILER
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
2210 Dwyer Avenue, Utica NY 13504-4729
Phone: (315) 797-1310 • Fax: (866) 432-7329
e-mail: info@ecrinternational.com
web site: www.ecrinternational.com
USER'S
MANUAL
SERIES DV
Utica Boilers
P/N 37615901, Rev. B [3/2011]

Advertisement

loading

Summary of Contents for UTICA BOILERS DV

  • Page 1 USER'S INFORMATION MANUAL SERIES DV GAS FIRED HOT WATER HEATING BOILER WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2: Safety Symbols & Warnings

    INSTRUCTIONS FOR OPERATION AND MAINTENANCE OF GAS FIRED HOT WATER HEATING BOILER RETAIN FOR FUTURE REFERENCE Utica Boilers recommends all boiler maintenance be SAFETY SYMBOLS & WARNINGS performed by a trained heating technician. Following defined symbols are used throughout this manual Before any procedures are attempted on this appliance, to notify reader of potential hazards of varying risk levels.
  • Page 3: Lighting Instructions

    LIGHTING INSTRUCTIONS This appliance is equipped with an ignition device which WARNING automatically lights the pilot. Do not try to light pilot by hand. Before lighting any type of pilot burner (standing or intermittent), make certain hot Remove jacket front panel. water boiler and system are full of water to minimum pressure of 12 lbs.
  • Page 4: To Turn Off Gas To Appliance

    LIGHTING INSTRUCTIONS To Turn Off Gas To Appliance Set the thermostat to lowest setting. Turn off all electric power to the appliance if service is to be performed. Push in gas control knob slightly and turn clockwise to "OFF." DO NOT FORCE. Replace jacket panel.
  • Page 5 GENERAL INSTRUCTIONS Before seasonal start up it is advisable to have qualified Visual check of main burner and pilot flames should be service agency check boiler for soot and scale in the flues, made at start of heating season and again in mid-season. clean burners and check gas input rate to maintain high operating efficiency.
  • Page 6 GENERAL INSTRUCTIONS Figure 4 - Burners, Burner Orifices Figure 5 - Boiler Front with Safety Switch VENT PIPE ADAPTER JACKET FRONT BURNERS PANEL COMBUSTION CHAMBER BURNER DOOR (REMOVED) GAS VALVE ORIFICES BURNERS VALVE BURNER ROLL-OUT SAFETY SWITCH Figure 6 - Burner Flame Figure 7 - Burners Pilot Flame 3/8”...
  • Page 7 NOTES...
  • Page 8 NOTES Date of Installation: Boiler Model #: Installed By: Utica Boilers 2210 Dwyer Avenue, Utica NY 13504-4729 Phone: (315) 797-1310 • Fax: (866) 432-7329 e-mail: info@ecrinternational.com web site: www.ecrinternational.com...