Step 5. Connecting Gas Line - Lennox Hearth Products MNTSVBE User Manual

B-vent multi-open elite series
Table of Contents

Advertisement

FIREBOX BOTTOM
JUNCTION BOX
OUTLET RECEPTACLE
OUTLET RECEPTACLE
BOX SECURING SCREW
EBST-2, EBPF-2
AND EBCL-2 OUTLET RECEPTACLE SHOWN.
EBCR-2 HAS THE OUTLET RECEPTACLE LOCATED IN
THE LEFT CORNER OF THE UNIT
EBBAY OUTLET RECEPTACLE LOCATED IN
THE REAR LEFT CORNER OF THE UNIT
VIEW OF RIGHT BOTTOM CORNER OF UNIT
OUTLET RECEPTACLE INSTALLATION
Figure 17
10. If wall-mounted ON/OFF switch or thermo-
stat is to be used, mount it in a convenient
location on a wall near the fireplace.
CABINET
RIGHT SIDE
11. If the wall-mounted ON/OFF switch is to be
PANEL
used, wire it to the the low voltage circuit
as shown in Figure 18.
Note: The supplied 15 feet of 2 conductor wire
has one end of each conductor connected to
the gas valve circuit and the other end of each
conductor placed loose inside the lower com-
partment of the unit.
12. After wiring is complete, reinstall the out-
let receptacle; install the field-provided
the metal junction box cover plate; rein-
stall the modesty panel.
Note: The gas valve ON/OFF switch is shown in
Figure 18. It is integral with the gas valve and
should be set to the ON position.
IMPORTANT: Ground supply wire must
be connected to the green wire attached
to the outlet receptacle's green ground
screw. See Figure 18 . Failure to do so
will result in a potential safety hazard.
The appliance must be electrically
grounded in accordance with local codes
or, in the absence of local codes, the
National Electrical Code, ANSI/NFPA 70-
(latest edition). (In Canada, the current
CSA C22-1 Canadian Electrical Code.)
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Electronic Wiring Diagram (Honeywell)
1. If any of the original wire as supplied must be replaced,
1.
it must be replaced with Type AWM 105 C – 18 GA.
wire.
2. 120V, 60Hz – Less than 3 amps.
*Leave the ON/OFF switch, which is integral
with the gas valve, in the ON position.
*ON/OFF Switch (Integral
with Gas Valve)
Gas Valve
PILOT
ASSEMBLY
BK
R
Green
BL
White
Black
Tab Intact
Tab
Broken
Red
Green
Hot
Neutral
Ground
Side of
Side of
Screw
Receptacle
Receptacle
W
B
G
BL
R
WT
WT
LIMIT SWITCH
**OPTIONAL WALL SWITCH
OR OPTIONAL THERMOSTAT
OR OPTIONAL REMOTE
APPLIANCE-MOUNTED ON/OFF SWITCH
**Turn the appliance-mounted ON/OFF burner control switch to
the OFF position if an optional control switch is installed.
Factory Wired
Schematic Representation Only
Figure 18

Step 5. CONNECTING GAS LINE

Make gas line connections. All codes require a
shut-off valve mounted in the supply line.
Figure 19 on page 12 illustrates two methods
for connecting the gas supply. The flex-line
method is acceptable in the U.S., however,
Canadian requirements vary depending on lo-
cality. Installation must be in compliance with
local codes.
G
o r
n u
- d
G
e r
n e
N
e
t u
a r
- l
W
h
e t i
120 VAC - Black
Junction Box
Optional
Accessory
Switch
Transf.
120 V.
24 V
BK
RECEIVER
Field Wired
11