Technical Data - Baxi Brazilia F 5 Installation And Servicing Instructions

Balanced flue gas wall heaters
Table of Contents

Advertisement

© Baxi Heating U.K. Limited 2007.
F 5 & F 5S Natural Gas
II
Category of Appliance
2H3P
The appliance is set for Gas Type G20 at 20mbar.
Heat Input (gross)
High
kW
2.05
Btu/h
7,000
Heat Output (gross) High
kW
1.5
Btu/h
5,100
Setting Pressure
Cold
mbar
in wg
Injector Size
CO
2
Nox Class
3
Gas Rate
on HIGH
0.195 m
Gas Connection
R
/
1
4
Ignition
Piezo Spark
Packed Weight
F 5
18 kg
(39.7 lbs)
Dimensions
F 5
Height
394mm
Width
426mm
Depth
126mm
(from the wall)
Controls
Rotary gas tap allowing
manual adjustment
between low, medium
and high output.
Flame failure device.
Thermocouple
Output
8-13mv
Heat Exchanger
Cast Iron
B.S. Codes of Practice
STANDARD
SCOPE
B.S. 6891
Gas Installation.
B.S. 5440: Pt. 1
Flues.
B.S. 5871 Pt.1
Installation of fires, convector
heaters
F 8S & F 8ST Natural Gas
Category of Appliance F 8S II
Category of Appliance F 8ST I
The appliance is set for Gas Type G20 at 20mbar.
Med
Low
1.41
0.86
Heat Input (gross) High
4,800
3,000
Med
Low
0.98
0.57
3,350
1,950
Heat Output (gross) High
19.7 ± 0.75
7.9 ± 0.3
Setting Pressure
F Range
Setting Pressure
Comfort Stat
3
/h (6.89 ft
3
/h)
(
/
BSP external)
1
4
Injector Size
Nox Class
F 5S
18.4 kg
Gas Rate
(40.6 lbs)
on HIGH
F 5S
Gas Connection
394mm
450mm
Ignition
128mm
Packed Weight
Dimensions
Controls
Non Thermostat
Controls
Comfort Stat
Thermocouple
Output
Heat Exchanger

2.0 Technical Data

Except
Comfort
Stat
Med
kW
3.06
2.21
Btu/h
10,440 7,540 5,290 4,333
Except
Comfort
Stat
Med
kW
2.26
1.48
Btu/h
7,700 5,050 3,412 2,730
Cold
mbar
in wg
Cold
mbar
in wg
CO
1
2
0.29 m
R
1
/
(
1
/
4
Piezo Spark
F 8S & F 8ST
24.4 kg
(54 lbs)
F 8S & F 8ST
Height
430mm
Width
516mm
Depth
152mm
(from the wall)
Rotary gas tap allowing
manual adjustment
between low, medium
and high output.
Flame failure device.
Rotary thermostat allowing
a preset position and
adjustment between low and
high temperature settings.
Flame failure device.
8-13mv
Cast Iron
2H3P
2H
Comfort
Stat
Preset Low
1.55
1.27
Comfort
Stat
Preset Low
1
0.80
19.25 ± 0.75
7.7 ± 0.3
17.25 ± 0.75
6.9 ± 0.3
3
/h (10.28 ft
3
/h)
BSP external)
4
5

Hide quick links:

Advertisement