Annual Servicing - Baxi Brazilia F 5 Installation And Servicing Instructions

Balanced flue gas wall heaters
Table of Contents

Advertisement

© Baxi Heating U.K. Limited 2007.

6.0 Annual Servicing

6.1
Servicing the Appliance
1. For reasons of safety and economy the
appliance should be serviced annually
2. Before servicing please read Section 1.3
Important Information.
Outer Case
3. Turn off the gas supply and ensure that the
appliance is cold.
Fig. 14
4. Remove the control knob by pulling forward,
then remove the case by easing upwards and
forwards until it is clear of its retaining lugs
(Fig. 14).
Control Knob
5. Undo the heat exchanger retaining nuts and
washers (Fig. 15) and draw the casting forwards
off the locating studs.
6. Remove the three screws holding the burner
retaining plate to the airbox and undo the
thermocouple nut from the gas tap (Fig. 16 & 19).
7. Ease the thermocouple and electrode lead
Fig. 15
from the rubber grommet (Fig. 17).
Rope Seal
8. Disengage the burner from the injector and pull
Heat Exchanger Casting
the electrode lead off the spark electrode
(Fig. 16).
Burner Retaining Plate
9. Check that the insulation is undamaged.
Replace if necessary. (F 8S & F 8ST only -
Fig. 16
Check that the aluminium foil is undamaged.
Replace if necessary) (Fig. 18).
Burner Gauze
10. Remove and clean the injector and sealing
washer. The injector must not be cleaned with a
Spark
needle or wire (Fig. 19). If the sealing washer is
Electrode
damaged it must be replaced.
Flue Outlet Tube
11. Check that the flue outlet tube is clear
(Fig. 18).
Burner Flame Ports
Insulation
12. Brush away any dirt from the heat exchanger
casting. If necessary clean the viewing window.
13. With a light brush carefully remove deposits
Fig. 17
from the spark electrode, burner flame ports and
the burner gauze (Fig. 16).
14. Replace the rope seal in the heat exchanger
casting if it is damaged in any way (Fig. 15). Also
examine the thermocouple and replace if
necessary.
Grommet
15. Re-assemble the injector, washer and burner
Electrode Lead
assembly in reverse order of dismantling. Ensure
that the spark gap is correct ie. 3.5mm ± 0.5mm.
Fig. 18
Thermocouple
Check that the burner is horizontal and correctly
positioned on the injector with the gauze covering
the primary aeration hole.
16. Check the gas pressure at the test point on
the gas control tap. If the pressure is not within
Gas Tap
the tolerance, (see Section 2.0 Technical Data)
Thermocouple
the gas supply to the unit needs to be
investigated.
17. Check that the burner ignition is satisfactory.
Ensure that the thermocouple/electrode lead
grommet is correctly positioned and re-fit the heat
Fig. 19
Injector
exchanger casting.
18. Check for gas soundness.
Washer
19. Fit the case and control knob and re-check
Electrode Lead
that the ignition is satisfactory.
12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents