Bi-rich BR-CN116 Instruction Manual

Bi-rich BR-CN116 Instruction Manual

Mini compressor nebulizer

Advertisement

Mini Compressor Nebulizer
Instruction Manual
Model No.: BR-CN116
1

Advertisement

Table of Contents
loading

Summary of Contents for Bi-rich BR-CN116

  • Page 1 Mini Compressor Nebulizer Instruction Manual Model No.: BR-CN116...
  • Page 2: Table Of Contents

    Table of Contents IEC Symbols……………………………………………………..3 Important Safeguards……………………………………………3 Introduction……………………………………………………….4 Specifications…………………………………………………….4 Description………………………………………………………..5 Operation Instruction…………………………………………….6 Cleaning…………………………………………………………..6 Maintenance………………………………………………………7 Warranty…………………………………………………………...7 Disposal……………………………………………………………8...
  • Page 3: Iec Symbols

    IEC Symbols Caution Attention or Consult accompanying documents……. Type BF Equipment……………………………………………..Alternating Current………………………………………………… ~ Double Insulation……………………………………………………. Indoor use only……………………………………………………… Important Safeguards Caution: .Federal Law restrict this device for sale or use on the order of a physician. 2.Follow the instruction of your physician to operate this unit. 3.This product is a nebulizer for the inhalation of medical aerosols and is suitable for children used solutions.
  • Page 4: Introduction

    Warning: To reduce the risk of infection: 1. This Nebulizer kit is intended for both adult and pediatric patient use. 2. Cleaning of the nebulizer is recommended after each aerosol treatment. disinfecting is recommended once a day. Please follow cleaning and disinfecting instructions in this manual.
  • Page 5: Description

    Description 1. Air outlet connector 4.Power cord 7.Air inlet connector 2.Filter cap 5.Mouthpice 8.Tubing 3.Power switch 6.Nebulizer cup 9.Foam filters Accessories : Nebulizer Air tube Adult mask Pediatric Nebulizer T-Mouthpiece Carry bag 5pcs machine mask filters...
  • Page 6: Operation Instruction

    Operation Instructions 1. Place compressor on a stable, sturdy and flat surface so that the unit can be easily reached when you are seated. 2. Pull out the power cord from the base of the unit ,and make sure that the unit is in the “...
  • Page 7: Maintenance

    Any defective part or assembly will be repaired or replaced at the sole discretion and determination of Shenzhen Bi-rich Medical Devices Co., Ltd if the unit has been properly operated during the warranty period. Normal maintenance items and disposable components are not covered by this warranty.
  • Page 8: Disposal

    Aerosol Output: **over 0.33 ml (2ml,1%NaF) Aerosol Output Rate: **0.06ml/min (2ml,1%NaF) Bi-rich Compressor nebulizer the particle size distribution curve as well: Result of cascade impactor **measurements for particle size with Bi-rich Compressor nebulizer and nebulizer kits MMAD = Mass Median Aerodynamic Diameter...