WIKORA GS 117 E Installation Manual Operating Instructions

Advertisement

Installation manual
Operating instructions
Index
1
General ................................................................................................................................................................................ 2
2
Transport and installation .................................................................................................................................................... 2
3
Dimensions and connections .............................................................................................................................................. 3
4
Technical data ..................................................................................................................................................................... 4
5
Installation ........................................................................................................................................................................... 5
6
Commissioning .................................................................................................................................................................... 7
7
Gas regulation ..................................................................................................................................................................... 8
8
Conversion to other gas types ............................................................................................................................................. 9
9
Technical data - Gas ......................................................................................................................................................... 10
10
Convertion kits .................................................................................................................................................................. 10
11
Maintenance and wear parts ............................................................................................................................................ 11
12
User Information ............................................................................................................................................................... 11
13
Faults ................................................................................................................................................................................ 11
14
Warranties and guarantee ................................................................................................................................................ 13
15
Installation record ............................................................................................................................................................. 14
© Wikora GmbH
Gas Boiler
GS 117 E / GS 152 E / GS 192 E
Installation,
must be undertaken by a specialist.
The boiler must be connected according to the
regulations in force and may only be operated in
well vented areas.
Control devices must be checked for functioning.
Fittings, immersion sleeves, connection seals, drain
valve etc must be checked and if necessary
retightened or resealed.
General terms and conditions of warranty state that
all installations must be carried out by a suitably
trained and qualified plumber who observes the
local norms and regulations.
The installation and maintenance record must
be entirely completed and the user has to be
instructed accordingly.
Efficient operation can only be guaranteed if the
instructions of this manual are followed.
Warranty does not cover any damage caused due
to non-observance of this manual and the technical
rules in force.
The system is to be checked annually by a
specialized company. In addition, occurring defects
must be repaired immediately.
This document should be handed over to the
client on completion of the installation.
.
Page 1
Phone: (07322) 9605-0
Fax: (07322) 9605-30
email: contact@wikora.de
calibration
and
commissioning
As at November 2013
Errors excepted.
WIKORA GmbH
Friedrichstr. 9
89568 Hermaringen

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GS 117 E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for WIKORA GS 117 E

  • Page 1: Table Of Contents

    Phone: (07322) 9605-0 Fax: (07322) 9605-30 email: contact@wikora.de Installation manual Gas Boiler Operating instructions GS 117 E / GS 152 E / GS 192 E Installation, calibration commissioning must be undertaken by a specialist. The boiler must be connected according to the regulations in force and may only be operated in well vented areas.
  • Page 2: General

    The tank must be disconnected from any humidity carrying components. Any light flammable material must be placed at least one meter away. Moreover, sufficient space for maintenance and cleaning must be kept unobstructed at the front, the sides, above and behind the boiler. © Wikora GmbH Page 2 As of November 2013...
  • Page 3: Dimensions And Connections

    [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] 1140 1140 1140 1208 1100 GS 117 E 1396 1396 1396 1464 1356 GS 152 E 1713 1713 1713 1781 1673 GS 192 E Chart 1 Connections: Type...
  • Page 4: Technical Data

    4 Technical data Type GS 117 E GS 152 E GS 192 E Capacity [liter] ca. 115 ca. 150 ca. 190 Max. working pressure [bar] Output [kW] 7,12 8,12 9,18 Input (gross) [kW] 10,2 Flue gas temperature [° C] Flue gas volume...
  • Page 5: Installation

    160mm. No covers are to be placed over nor are any alterations to be made to the flow operated safety device. Illustration 2 © Wikora GmbH Page 5 As of November 2013...
  • Page 6 2 minutes. This check should be carried out swiftly and the area needs to be aired sufficiently (danger of suffocation). 5.6 Exhaust fume cap By installation of a flue gas damper only use Diemayer-damper HOK 80 W DIN-DVGW-Reg.-No. 86.02e 003! (Wikora part number 090062).
  • Page 7: Commissioning

    It is recommended to keep the tank operated outside the noticeable condensate area between position 5 and 6 which corresponds to ca. 60° C. © Wikora GmbH Page 7 As of November 2013 Errors excepted.
  • Page 8: Gas Regulation

    22a Piezo spark ignition 33 Ignition gas line 23 Marking for ignition setting 34 Ignition cable 24 Marking for OFF position 36 Capillary tube for temperature sensor 25 Cover cap Volumetrische Methode © Wikora GmbH Page 8 As of November 2013 Errors excepted.
  • Page 9: Conversion To Other Gas Types

    (page 8). Replace cover cap (25) and fix screws. 8.3.3 Place new sticker „Type of gas“ on the gas fittings. 8.3.4 Replace cover plate (15) and open gas cock. © Wikora GmbH Page 9 As of November 2013 Errors excepted.
  • Page 10: Technical Data - Gas

    *Net heating value H at gas volume at 15° C, 1013 mbar dry. 10 Conversion kits GS 117 E / GS 152 E /GS 192 E- execution with gas fittings EUROSIT 630, stainless steel burner and LOW-Energy-pilot burner. GS 117 E...
  • Page 11: Maintenance And Wear Parts

    This also applies during the period when the appliance is still covered under warranty. In case of warranty the company will cover the costs raised by customer services. © Wikora GmbH Page 11 As of November 2013 Errors excepted.
  • Page 12 Gas connecting pipes have a too small dimension Adjust dimensions of connecting pipes The filter in the regulator is blocked Clean filter Pressure regulator defect Replace gas control fittings © Wikora GmbH Page 12 As of November 2013 Errors excepted.
  • Page 13: Warranties And Guarantee

    Under condition that the limits of the valid DHW regulations have been respected, the anode has been examined for the first time after 2 years and afterwards annually and that the anode has been replaced by an original Wikora anode (individual receipts needed) by a specialized company.
  • Page 14: Installation Record

    In the case of reclamation, the receipts for maintenance must be provided as proof. Please complete the data sheet, including the reason for reclamation, and submit to Wikora. Submitting the maintenance record does not ensure any promise of guarantee or claim.

This manual is also suitable for:

Gs 152 eGs 192 e

Table of Contents